ON/OFF Switch

ON/OFF switch (A) controls ignition system.
ON Position:
Ignition circuit is switched on. Engine can be
started.
OFF Position:
Ignition circuit is switched off. Engine will not
run.
Stopping
1. Disconnect plugs from electrical sockets (B &
D) to let engine run under no load for 1 or 2
minutes.
2. Set ON/OFF switch (A) to OFF position:
generator stops.
3. Close fuel valve (R).

Maintenance Instructions

Accidental Starts can cause
severe injury or death.
Disconnect and ground spark
plug lead(s) before servicing.
Safety is an obligation of owner. Periodic inspection, adjustment and lubrication will keep your
generator in safest and most efficient condition possible. Most important points of generator
inspection, adjustment, and lubrication are explained on following pages.

Maintenance Schedule

After first 5 Hours
● Change oil.
Every 100 Hours or Annually
● Clean low-profile air cleaner element (P).
● Change oil.
● Clean cooling areas.
Every 200 Hours
2
● Check and adjust valve clearance when engine is cold.
Every 300 Hours
● Replace low-profile air cleaner element (P).
● Check fuel filter (S) and clean or replace if needed.
Every 500 Hours or Annually
● Replace spark plug (K) and set gap.
Perform these procedures more frequently under severe, dusty, dirty conditions.
1
Have a Kohler portable dealer perform this service.
2
6
WARNING
1
1
KohlerPower.com

High Altitude Operation

This generator may require a high altitude
carburetor kit to ensure correct engine
operation at altitudes above 4000 ft. (1219
meters). To obtain high altitude kit information
or to find a Kohler portable dealer go to
KohlerPower.com or call 1-800-544-2444.
This generator should be operated in its original
configuration below 4000 ft. (1219 meters) as
damage may occur if high altitude carburetor
kit is installed and operated below 4000 ft.
(1219 meters).
Engine Speed
NOTE: Do not tamper with governor setting to
increase maximum engine speed.
Overspeed is hazardous and will void
warranty.
Before working on engine or equipment, disable
engine as follows: 1) Disconnect spark plug
lead(s). 2) Disconnect negative (–) battery cable
from battery.
37 590 02 Rev. F