Technical Specifications - Festo CP FB6-E Breve Descripción

Ocultar thumbs Ver también para CP FB6-E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
CP FB6-E
5

Technical specifications

Type
Protection class (as per DIN 40050)
Ambient temperature
Storage temperature
Pin 1 - Operating voltage connection
for electronic components/inputs
• Rated value
(protected against incorrect polarity)
• Tolerance
• Permitted current consumption
Pin 2 - Operating voltage connection
for outputs/valves
• Rated value
(protected against incorrect polarity)
• Tolerance
• Permitted current consumption
Electromagnetic compatibility (EMC)
Resistance to suppression
• tested as per EN 55011
Resistance to interference
• tested as per EN 50082-2
18
CP FB6-E
IP 65
o
o
- 5
... + 50
C
o
o
- 20
... + 70
C
DC 24 V
DC 20,4 V...26,4 V
250 mA
DC 24 V
DC 20,4 V...26,4 V
Sum of all switched
CP solenoid valves
Limit value severity A
9709 NH

Publicidad

Tabla de contenido
loading