Technical specifications

Type
Temperature range
Operation
Storage
Relative humidity
Protection class as per EN 60529 plug
connector inserted or provided with
protective cap
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204−1/IEC 204)
Protection against explosion
(as per EU guideline 94/9/EG,
EN 50021 and EN 50281−1−1). Do not
disconnect electrical connections which
are under tension.
Electromagnetic compatibility
Interference emitted
Resistance to interference
*)
The CPV Direct is intended for use in industrial installations.
Festo CPV..−GE−IP−8 0211NH English
CPV..−GE−IP−8
− 5 ... + 50° C
− 20 ... + 70 °C
95 %, non−condensing
IP65
With a PELV power unit
(Protected Extra Low
Voltage)
II 3 G/D EEx nA II T5 X
−5 °C Ta +50 °C
T 80 °C IP65 (year of manu
facture see Ex−identification
on the product)
Tested as per EN 61000−6−4
*)
(industry)
Tested as per EN 61000−6−2
(industry)