DIGITAL THERMOMETER
Model MC-246
5328583-4A
Thank you for purchasing Omron Digital Thermometer.
The thermometer you purchased offers a safe, accurate and quick temperature reading. You can measure your temperature through oral, rectal or
underarm. This thermometer eliminates any worries about broken glass or mercury hazards. Note that your temperature is affected by smoking, eating
or drinking. Thoroughly read this instruction manual before using your OMRON MC-246 Digital Thermometer. We recommend that you practice
taking your temperature with the thermometer when you are healthy. In this way you will gain confidence in your technique when using the
thermometer. Contact your doctor if you have any questions regarding specific temperatures. The thermometer is provided non-sterile.
IMPORTANT SAFETY NOTES
To assure the correct use of the product basic safety, measures should always be followed including the precautions listed below.
WARNING
• A high or prolonged fever requires medical attention, especially for young children. Please contact your doctor.
• Carefully read and follow the enclosed instructions to ensure accurate temperature readings. Note that temperature readings are affected by many
factors including physical exertion, the drinking of hot or cold beverages before measurement, as well as measuring technique.
• Please keep still during measurement.
• The use of temperature readings for self-diagnosis is dangerous. Consult with your doctor for the interpretation of results. Self-diagnosis may lead to
the worsening of existing disease conditions.
• This thermometer is used for taking temperatures through oral, rectal or underarm. Do not attempt to take temperatures at other sites, such as in the
ear, as it may result in false readings and may lead to injury.
• Store the thermometer out of the reach of children. Do not allow children to take their temperatures unattended. Children may injure themselves
when attempting to take temperatures without supervision.
• Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
CAUTION
• Do not bite on the thermometer. Doing so may lead to breakage and/or injury.
• Do not share the thermometer among individuals.
• Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
• Do not attempt to incinerate the battery. It may burst.
• Pay attention to polarity (+ –) when replacing the battery. Failure to do so may lead to fluid leakage, heat generation or bursting, resulting in damage
to the unit.
• Remove the battery when the thermometer will not be used for 3 months or more. Failure to do so may lead to fluid leakage, heat generation or
bursting, resulting in damage to the unit.
• Do not use mobile phones near the thermometer.
• Do not use the thermometer in places where strong static electricity or electromagnetic fields are present. Doing so may lead to inaccurate readings
and may contribute to instrument failure.
• Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present. Failure to do so may lead to injury.
• Do not attempt rectal measurements on persons with rectal disorders. Doing so may aggravate or worsen the disorder.
• Do not step on the unit or the storage case.
• Do not attempt to disinfect the sensing section of the thermometer by immersing in alcohol or in hot water (water over 122°F).
GENERAL SAFETY PRECAUTIONS
• Do not use the thermometer to measure anything other than human body temperatures.
• Do not drop the thermometer and storage case or expose them to shock or vibration.
• Do not store the thermometer in the storage case when it is damp. Wipe it off with a dry cloth first.
• Avoid taking the temperature until after 30 minutes has lapsed after exercise, bathing or eating/drinking.
SWITCHING BETWEEN FAHRENHEIT/CENTIGRADE (CELSIUS)
Press the
button for 7 seconds until a beep is emitted.
The display will change to the other measurement scale at the
time when the beep sounds.
94
96
98
100
102
104
°F
95
97
99
101
103
105
FAHRENHEIT/CENTIGRADE CONVERSION CHART
°C
35.0
36.1
37.2
38.3
39.4
40.6
34.4
35.6
36.7
37.8
38.9
40.0
UNDERARM (AXILLARY) USE:
• Place the probe tip in the center of the armpit.
Turn the display so
that it faces
inwards.
• Lock the probe tip under the arm, using the arm to slightly apply
pressure inwards.
Thermometer Angle
The angle should be
35-45 degrees in
relation to the arm.
* In the case of infants and very young children, gently hold the
arm to prevent movement.
BATTERY REPLACEMENT
Battery:
Alkaline-Manganese Button Battery LR41 (available commercially)
Battery Replacement Indicator (
)
Replace the battery when the battery replacement indicator appears when the thermometer is switched on.
1.
Use a coin to take off the battery cover.
Battery Cover
Coin
2.
Remove the battery.
ERROR DISPLAYS
INDICATOR
CAUSE
Displayed when the temperature of the sensing section is less than
89.6°F (32°C).
Displayed when the temperature of the sensing section is greater
than 107.6°F (42°C).
Temperature
Displayed when the surrounding temperature exceeds
Displayed
89.6°F (32°C).
Button
Display Window
Probe Tip
Accessory: Storage Case
All of the display symbols
Beep
appear.
After 5 seconds
After 2 seconds
The thermometer will
Beep
automatically switch itself off.
°F to °C °C to °F
INCORRECT MEASUREMENTS
Taking the temperature immediately after exercising,
bathing, eating or drinking will result in an incorrect
measurement.
Correct: Wait at least 30 minutes before taking the
temperature.
Taking the temperature after moving around.
Correct: Take the temperature immediately after waking up
or wait for at least 30 minutes after moving around.
* Moving around after awakening increases the body
temperature.
- Only applies when taking underarm
temperatures -
The following may result in incorrect measurements.
Heavy underarm perspiration
Taking the temperature after being under the blankets
for a long time.
Correct: Wipe off any underarm perspiration before
taking the temperature.
3.
Insert the new battery with the "+" pole
facing up as shown in the diagram.
4.
Use a coin to replace the battery cover.
NOTES:
Battery
• The thermometer comes fitted with a battery for testing purposes.
This battery may not provide the same amount of battery life as a
new battery.
• Consult your local authorities and follow their instructions for the
disposal of batteries and/or the thermometer.
• Do not loose the O-ring around the battery
cover. Water-resistant will fail and can lead
to misreading and failure of the unit.
REMEDY
This is not an error so it may be ignored and the temperature taken.
Cool the sensing section and then take the temperature.
This is not an error, so the temperature may be taken as is.
TAKING THE TEMPERATURE
1.
Press the
button.
A default temperature 98.6°F (37.0°C) is shown
on display.
NOTE:
When a temperature other than 98.6°F (37.0°C)
is displayed, please refer to the
"TROUBLESHOOTING" section for details to correct the
problem.
2.
Apply the thermometer to the measurement site.
Use the oral, rectal or underarm site for measurement.
NOTE:
Even if the "L" indicator fails to display (when only the
temperature is displayed),
this is not an error. So the
temperature may be taken as is.
3.
When the reading is ready, the thermometer will emit a
[beep-beep-beep] sound three times. Remove the
thermometer from the measurement site and read the
result.
BUZZER NOTIFICATION TIMING
Oral : approx. 60 seconds
NOTES:
• The buzzer notification timing is based on an environmental temperature of 73.4 °F.
• There will be individual differences in the measurement results.
4.
Turn off the thermometer and store it in the storage case.
NOTES:
• The reading will automatically be stored in memory.
• Although the thermometer will automatically switch itself off 30 minutes after use or after 3 minutes when it has not been used; it should be
turned off manually to conserve the battery.
DISPLAYING THE LAST TEMPERATURE
Press the
button to display the temperature that was measured most recently.
For details, please refer to the "TAKING THE TEMPERATURE" section.
CORRECT MEASUREMENT
Measurement accuracy cannot be assured when the method used to measure the temperature is incorrect.
ORAL USE (for ages 4 and older):
The mouth should remain closed up to 5 minutes before attempting a reading.
• Place the thermometer in the mouth under the tongue so that it rests to the left or right of the root of the
tongue.
• Use downward tongue pressure to hold the thermometer in place.
• Hold the thermometer to keep it from sliding around in the mouth.
RECTAL USE:
• Commonly used for young children when it is difficult to take an oral or underarm temperature.
• Lubricate with a water-soluble gel. Do not use petroleum jelly.
• Gently insert the probe tip no more than 1/2 inch into the rectum. Do not force the tip into the rectum if resistance is encountered.
• Disinfect the thermometer after use. For details, please refer to the "CARE AND MAINTENANCE" section.
TROUBLESHOOTING
PROBLEM
Wide differences in readings
Nothing appears in the display
section when the power switch is
pressed.
[98.6°F (37.0°C)] is not displayed
during the measurement
preparation period.
CARE AND MAINTENANCE
Keep the thermometer clean.
• Do not use strong jets of water to clean the thermometer or leave it immersed in water for
long periods of time.
• Wipe the thermometer with a soft clean cloth.
• When using alcohol to clean the thermometer, make sure that it does not come into contact
with the indicator section.
• For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or
a neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.
• Observe the following to prevent damage to the thermometer.
- Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.
- Do not soak the sensing section in alcohol for long periods of time or attempt to sterilize it
using hot water (water at a temperature of 122°F (50°C) or higher).
- Do not use ultrasonic washing to clean the thermometer.
The "+" mark
Cleaning and disinfection
faces upwards
• Omron recommends to wipe the device with damp cloth. For disinfection, 70% Ethanol or
Isopropyl alcohol can be used. Do not attempt to disinfect the sensing section of the
thermometer by immersing in alcohol or in hot water (water over 122°F).
LIMITED WARRANTIES
Your new digital thermometer, excluding the battery, is guaranteed to be free from manufacturers defects for one year under normal use. This warranty extends only
to the original retail purchaser. We will, at our option, repair or replace without charge any thermometer. To obtain warranty service contact Customer Service by
calling 1-800-634-4350 for the address location and the return shipping and handling fee.
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY ABOVE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES
OR DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.
SPECIFICATIONS
Product Name:
DIGITAL THERMOMETER MC-246 (MC-246-Z)
Power Consumption:
0.1mW
Sensing Unit:
Thermistor
Temperature Display:
4-digit (°F), or 3-digit (°C) display in 0.1 degree
increments
Measurement Accuracy: ± 0.2°F (89.6 to 107.6°F)
± 0.1°C (32.0 to 42.0°C)
(when measured at a standard room temperature of 73.4°F
O-ring
(23°C) in a test tank held at constant temperature)
89.6 to 107.6°F (32.0 to 42.0°C)
Measurement Range:
Surrounding temperature +50 to +104°F (+10 to +40°C), Relative Humidity 30-85%RH
Usage Environment
Temp and Humidity:
Storage Environment
Surrounding temperature –4 to +140°F (-20 to +60°C), Relative Humidity 10-95%RH
Temp and Humidity:
Weight:
Approx. 0.42 OZ ((12g) with battery installed)
0.76"(w) × 5.22"(l) × 0.39"(d) (19.4 mm (w) x 132.5 mm (l) x 10.0 mm (d))
External Dimensions:
Accessories:
Test Battery (Alkaline-Manganese Button Battery LR41), Storage Case, Instruction Sheet.
The specifications may be changed without prior notice.
Manufactured by OMRON HEALTHCARE
Made in China
Beep
Blinking
Indicator stays lit
Beep-beep-beep
Rectal : approx. 35 seconds
Underarm : approx. 75 seconds
CAUSE
• The temperature sensing part of the thermometer is
being placed at a different location for each reading.
Check to see that the thermometer is being placed at
• The thermometer is moved while the temperature is
the location as described in the "CORRECT
being taken.
MEASUREMENT" section.
• The mouth is kept open while the measurement is in
progress.
Take out the battery and replace using the correct
The polarity
is reversed.
polarity.
Check to see if
The battery is depleted.
Replace with a new battery (LR41).
A temperature from [98.4°F (36.9°C)] to [98.8°F (37.1°C)]
The thermometer may be used as it is.
is displayed.
A temperature other than that in the range from
Please contact your nearest authorized OMRON
[98.4°F (36.9°C)] to [98.8°F (37.1°C)] is displayed, even
dealer.
after turning the thermometer on and off several times.
Store the thermometer in its storage case.
• Do not store the thermometer in the following types of
places. Doing so may damage the thermometer.
- Wet locations.
- Locations with high heat and humidity or those that are
- Locations where the unit will be subjected to leaning,
- Pharmaceutical storage areas or locations where
Power Supply:
Battery Life:
Measurement Method:
Applied Part:
Distributed by :
Toll Free Customer Service:
OMRON HEALTHCARE, INC.
1-800-634-4350
1200 Lakeside Drive
www.omronhealthcare.com
Bannockburn, Illinois 60015
Copyright © 2009 Omron Healthcare, Inc.
All of the display symbols
appear.
°C
The most recently measured
temperature is displayed
together with the M indicator.
Waiting for use.
°C
When the [°F (°C)] indicator
symbol blinks, the
thermometer is ready for use.
Temperature measurement
will commence and the
[°F (°C)] indicator symbol
will blink.
°C
The [°F (°C)] indicator symbol
will stop blinking and stay on
when the reading is ready.
Root of
The display section
Tongue
is faced upwards.
Placement Points
Tongue
CORRECTION
appears in the display section.
exposed to direct sunlight. Areas close to heating
equipment, dusty locations, or environments where
there are high salt concentrations in the air.
shock or vibration.
corrosive gases are present.
1.5V DC, 1 LR41 Alkaline-Manganese Button Battery
Approx. 2 years or more (3 times per day)
Actual measurement
=Type B

Publicidad

loading

Resumen de contenidos para Omron MC-246

  • Página 1 NOTE: thermometer is ready for use. or drinking. Thoroughly read this instruction manual before using your OMRON MC-246 Digital Thermometer. We recommend that you practice Even if the “L” indicator fails to display (when only the taking your temperature with the thermometer when you are healthy. In this way you will gain confidence in your technique when using the...
  • Página 2 Tenga en cuenta que el fumar, comer o beber afecta su temperatura. Lea detenidamente este manual de instrucciones antes de usar su termómetro NOTA: digital MC-246 de OMRON. Le recomendamos que practique cómo tomar la temperatura con el termómetro cuando esté bien de salud. De esta Aunque no se visualice el indicador “L” (cuando se muestra La medición de la temperatura...