The error messages are displayed by the DL12 LED and the flashing light (terminal number 8 and 9).
Error message key:
Number of flashes
2
3
4
5
6
7
8
At the end of programming check the automatic gate system works properly by simulating the photocells and sensitive edges tripping. In the event of
malfunctioning, check the wiring, the dip switch 2-2 for selecting the direction of opening.
9 - Installing batteries
Insert the battery charging circuit in connector CN8 and connect the batteries, with battery-only operation the speed of the motor is 15% lower than the
speed with mains power, the number of operations with the batteries depends on the number of photocells in the system and the length of the gate. When
operating on batteries only, the AC LED is off, the 2CAN and AUX outputs are not active and the accessories are not supplied with the gate stationary.
Description
Force (adjusts the motor torque)
Slowdown speed
Cycle speed
Automatic closing time (adjustable from 1 to 120 seconds)
Description
Photocell test failed (incorrect wiring or photocells busy)
Detected a problem in the circuit that activates the motor
Problem with encoder (encoder not present or electric motor wiring reversed)
Serious error on EEPROM (U2 component missing or damaged)
The travel end time has elapsed (U2 component missing or damaged)