The alarm LED (53) fl ashes blue
Fault
"Rechargeable bat-
tery/battery fault"
Anl_GC_RM_500_SPK9.indb 41
Anl_GC_RM_500_SPK9.indb 41
GB
Possible cause
- There is a battery error on
the robot lawn mower
- The rechargeable battery
(22) does not charge up
- Poor charging pin (20) con-
tact
- The rechargeable battery
(22) has reached the end of
its service life
- 41 -
Remedy
Switch off the main switch (7) (OFF) and
then switch it back on (ON) again. Re-start
the mowing operation on the control panel
(2).
- Please check if there is a problem with the
power supply.
- Clean the charging pins (20).
- Replace the rechargeable battery (22) if
necessary.
- Contact your customer service center.
- Make sure that the rechargeable battery
(22) has been correctly fi tted
- Check whether the main switch (7) is ON
while the robot lawn mower is in the char-
ging station (19)
- Check the position of the charging station
(19) Replace the rechargeable battery
(22) if necessary.
16.02.2021 14:17:34