CONFIGURATIONS MENU "A"
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
----------------- CONFIGURATIONS MENU " A " --------------
Digit Reference
A1) NUMBER OF MOTORS
A2) TYPE OF MOTOR
A3) AUTOMATIC PGM
A4) TX CODE
A5) PEDESTRIAN TX CODE
A6) MOTOR T.
A7) PEDESTRIAN MOTOR T.
A8) PAUSE T.
A9) DOOR DELAY T.
A1 ) NUMBER OF MOTORS :
The default settings of the control unit have an operation
logic for connection of 2 Motors ( M1 + M2 DOT 2 Led off
). If operation logic is required for connection of one Motor
( M1 ) only by doubling the power available per motor (
DOT 2 on ), proceed as follows: set SEL and SET to
display A1 then press SET to select the function. At the
same time, DOT 1 will start to flash, press SET to change
the function, DOT 2 will remain permanently lit and the
operation will be complete. Repeat the procedure to
restore the previous configuration.
A2 ) TYPE OF MOTOR :
The default settings of the control unit have an operation
logic for connection of Linear Actuators (DOT 2 off). If
operation logic is required for connection of gear motor
connection with variable absorption
( DOT 2 on), proceed as follows: set
display A2 then press SET to select the function. At the
same time DOT 1 will start to flash, press SET to change
the function, DOT 2 will remain permanently lit and the
operation will be complete. Repeat the procedure to
restore the previous configuration.
A3) AUTOMATIC PGM:
With this control unit it is possible to carry out Automatic
Programming ( SIMPLIFIED). First place the automation
doors in an intermediate position and set SEL and SET to
display A3, then press SET to select the function. At the
same time, DOT 1 will start to flash, press SET, Motor 2
will close until reaching the limit switch or stop, followed
by the manoeuvre of Motor 1 repeated.
Should the motors move in a manner contrary to that
described, release the SET button, disconnect the power
supply to the control unit and connect the motor wires
correctly.
If the motor sequence is correct, the control unit
completes the Auto programming phase by executing a
complete opening and closing phase (hold the SET key
down until Auto Programming is finished).
At the same time, the Deceleration cycle is automatically
configured at 15% of the complete cycle.
During automatic programming, the Display scans the
operation seconds elapsed for each phase and Motor.
During programming the radio control key of the control
unit can be used instead of the SET key, if stored
previously.
A4 ) TX CODE : (Radio control code)
The control unit allows up to 150 radio-controls to be
memorised with different types of fixed, rolling codes or
Plus.
DOT 2 Off
DOT 2 On
M1 + M2
M1
Linear
Variable
NO
YES
NO
YES
NO
YES
30 sec.
PGM User sec.
10 sec.
PGM User sec.
30 sec.
PGM User sec.
NO
PGM User sec.
SEL and SET to
Programming.
Programming the transmission code is carried out as
follows: place the SEL and SET buttons to A4 display,
then press SET to select the function. At the same time,
DOT 1 and DOT 2 will start to flash. At this point, send the
selected code with the desired radio control. When DOT 1
and DOT 2 stop flashing, the DOT 2 LED will remain on
and programming will be complete.
If all 150 available codes have been memorised, by
repeating the programming operation, the Display will
view AF, indicating that it is not possible to memorise any
more codes.
A5 ) PED TX CODE: (Pedestrian radio control code)
The programming procedure is the same as the one
illustrated above except that it refers to the Pedestrian
Radio Control Code, function A5.
A6 ) MOT T. and DECELERATION:
operation time of max 4 minutes)
The control unit is supplied by the manufacturer with a
default motor operation time of 30 seconds, without
deceleration.
To modify the operation time of Motors 1 and 2, proceed
as follows when the gate is closed: set SEL and SET on
display A6, then press SET to select the function. At the
same time, DOT 1 will start to flash, press SET and DOT
2 will also start to flash, Motor 1 will start the Opening
cycle, (at the same time, the Display will scan the
operating seconds elapsed for every phase and motor).
Press the SET key again and the DOT 2 Display will start
flashing more slowly and Motor 1 will decelerate; when
the desired position is reached, press the SET key to
complete the Opening cycle.
Then DOT 2 will start flashing normally again and Motor 2
will begin its opening cycle:
program the work time for Motor 2.
After programming the opening times for the motors,
Motor 2 will start its closing cycle: repeat the same
instructions as above for programming the closing cycle of
Motor 2 and then for the closing cycle of Motor 1.
Important: If you do not want the control unit to
decelerate, press the SET key twice instead of once
during programming and on completion of the opening
and closing cycle, or previously disable deceleration (see
function C7), so that when programming motor time, the
deceleration phase will be automatically excluded.
During programming the radio control key of the control
unit can be used instead of the SET key, if stored
previously.
A7 ) PED MOT. T.:
(Programming a pedestrian operating time
of 4 minutes max.)
The control unit is factory supplied with a predefined
(Pedestrian) Motor 1 operating time of 10 sec. without
deceleration.
To modify the operation time of Pedestrian Motor 1,
proceed as follows when the gate is closed: set SEL and
SET on display A7, then press SET to select the function.
At the same time, DOT 1 will start to flash, press SET and
DOT 2 will also start to flash, Motor 1 will start the
Opening cycle, (at the same time, the Display will scan
the operating seconds elapsed for every phase and
motor). Press the SET key again and the DOT 2 Display
will start flashing more slowly and Motor 1 will decelerate;
when the desired position is reached, press the SET key
to complete the Opening cycle.
Then DOT 2 will start flashing again at its standard pace
again and Motor 1 will begin the Closing phase; repeat
the above operations for the Closing phase.
Important: If you do not want the control unit to
decelerate, press the SET key twice instead of once
during programming and on completion of the opening
12
(Programming a motor
repeat the operations to
Rev. 1.1