Installation
3

Trim Installation

A.
2
1
3
Slide O-ring (1) over cartridge and the
bonnet nut (2). The O-ring, which acts as
a spacer to steady the sleeve, should rest
behind the bonnet nut. Slide the sleeve
(3) over the cartridge, body and O-ring.
Ensure sleeve is properly positioned over
the front of cartridge.
C.
1
Install volume control handle (1) with lever
to the right, then turn to the on position.
DO NOT SECURE WITH SCREW.
B.
2
1
4
5
Escutcheon Installation for
Models T17053, T17253 & T17453.
6
5
7
9
8
Secure the escutcheon (1) and backplate (2)
(if your model has one) to the bracket (3) using
the 2 screws provided (4). Do not overtighten
escutcheon screws.If you are installing the
Cassidy models T17097, T17297 & T17497:
Thread the cover (5) onto the escutcheon (1).
For models T17053, T17253 & T17453:
Install bracket (5) over the cartridge body using
the 2 screws provided (6). Install escutcheon (7)
by placing it over the bracket as shown and
rotating it to lock the tabs (8). Secure the escut-
cheon to the bracket using set screw (9).
6
4
Installation and Adjustment of the Rotational Limit Stop
A.
3
1
Place the temperature control knob (1) on
volume handle and rotate to the mixed position
(if required). DO NOT SECURE WITH
SCREW. Turn on water supplies; let the water
run until both hot and cold water is as hot/cold
as possible. Place thermometer in a plastic
tumbler, and hold the tumbler in the water
stream. Record the temperature reading.
C-1
Secure temperature control knob (1) with
screw (2). snap on temperature control cover
8
(3) with side snaps onto knob (1).
C-2
1
5
2
4
Secure temperature control knob (1) with
screw (2). Hook (3) front of temperature
control cover (4) onto knob (1) before
engaging rear snap (5).
5
Potential scald or thermal shock injury could result due to cross flow if outlet at the
shower is blocked or restricted (e.g., pause control on showerhead). Be sure to point
showerhead away from you when re-starting flow or install inlet check valves on both
supply lines to prevent possible injury.
B.
1
Hotter
Colder
If the water temperature is above 120°F,
remove the temperature control knob (1)
and rotate the limit stop (2) clockwise one
1
tooth for every 4°F - 6°F (approximate)
2
change in temperature. If water temperature
3
is cooler than desired, rotate the limit stop
counterclockwise.
IMPORTANT: The first position of the
Rotational Limit Stop (the Limiter) is that
position that restricts the rotation of the
stem the most and is at the maximum
clockwise setting. According to industry
standards, the maximum allowable
temperature of the water exiting from the
valve is 120
in your local area. The Rotational Limit Stop
may need to be readjusted if the inlet water
temperature changes. For instance, during
5
the winter, the cold water temperature is
colder than it is during the summer which
could result in varying outlet temperatures.
Typical temperature for a comfortable bath
or shower is between 90
7
Installation
2
o
F. This temperature may vary
o
–110
o
F.