Fulgor Milano INCOGNITO 85 Instrucciones Para La Instalación Y Uso página 13

Campana integrada
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USES
The appliance is already arranged both for filte-
ring and for suction performances.
* In its filtering version (Fig. 1), the air and fu-
mes conveyed by the appliance are depured both
by a grease filter and by an active coal filter, and
put again into circulation through the hole made
on the top of the cabinet.
The charcoal filter is not supplied with the ap-
pliance.
* In its sucking version (Fig. 2), fumes are di-
rectly conveyed outside, through an evacuation
duct connected with the superior part of the wall
or the ceiling. Both coal filter and air deflector are
not necessary in this case.
INSTALLATION
Before installing the appliance, make sure that
none of the parts is damaged in any way.
In case of damaged parts, contact your retailer
and do not proceed with installation.
Read all of the following instructions with care be-
fore installing the appliance.
- Use an air outlet pipe of the shortest possible
length.
- Limit the number of pipe bends.
- Use a material approved by standards and re-
gulations.
- Avoid any sudden changes in pipe section (re
commended constant diameter: 150 mm or equal
surface area).
- The manufacturer shall not respond for air ca
pacity or noise problems due to non- compliance
with above mentioned instructions, and no war
ranty shall be given.
Remove the grease filters before installing the
product, in order to avoid to damage the applian-
ce.
Open the glass rotating it as shown in fig. 3; then
remove the grease filters acting on their specific
handle and rotate them to remove them from their
seating (fig. 4).
Make an opening on the kitchen cabinet bottom
of the following sizes:
SLTC919 520: 265mmX498mm
SLTC919 850: 265mmX835mm
Make sure the cabinet structure and the mate-
rial used allow you to make this opening without
causing any damages, even during the appliance
installation.
Prepare the power supply inside the cabinet.
Prepare the air discharge hole for the product
being installed either in the sucking or filtering
mode.
Use an air discharge pipe whose maximum leng-
th does not exceed 5 meters.
Limit the number of elbows in the piping, as each
elbow reduces the air capacity of the hood of
about 1 linear meter. (Eg.: if you use no. 2 x 90°
elbows, the length of the piping should not exce-
ed 3 meters).
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fbghd 850 tc x

Tabla de contenido