WATERHEAT SERIES · WATER/WATER SYSTEM
3.5.
HEAT EXCHANGER CONNECTION TO A FILTER/PUMP CIRCULATING
SYSTEM
• Connect the boiler cycle to the primary heat exchanger.
• Connect the heat exchanger secondary to the pool piping's by means of connections of tube
with tube clips or by means of inner spirals with connections of plastic/brass screw.
3.6.
HEAT EXCHANGER CONNECTION TO A FILTER CIRCULATING
SYSTEM
• Connect both heat exchanger boiler elements to the water boiler cycle
• Connect the heat exchanger secondary to the pool piping by means of connections of tube with
tube clips or by means of inner spirals with connections of plastic/brass screw.
3.7.

INSTALATION

• Hold the equipment through two M-6 blocks and M-4 clip, separated 220 mm. Hold the primary
and secondary pipes using clamps.
© ASTRALPOOL 2018 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.