INSTALLATION OF ACCESSORIES

9.1
Flue (Fig. 4)
The heater is provided with a flue connection.
1.
Fit a flue (B) to the flue connection (C).
Caution
The flue must point upwards. Never
place the flue horizontal. An angle of 45°
is acceptable; minimum length flue 40
inch.
2.
Fit a rain cover (A) to the end of the flue.
9.2
Diameter of the flue connection
/i
IMA 61
IMA 111
7 inch
8 inch
9.3
Outlet hose
An outlet hose must be fitted to the outlet of the
heater, in order to blow heated air to a remote
area away from the heater.
Caution
Check the temperature resistance of the
used hose.
Please contact the dealer for information about
maximum lengths of outlet hoses, bends,
distribution pipes and hose clamps.
9.4
Diameters of outlet hoses
/i
Number of
IMA 61
outlets
inch
∅ 16
1
∅ 12
2
3
-
4
-
/i
Back
IMA 61
pressure of
2
lb/ft
fan
8.35
9.5

Room thermostat

See the instructions of the room thermostat.
10

STANDARDS AND GUIDELINES

For the standards and guidelines, go to
www.thermobile.nl.
14
IMA 185
8 inch
IMA 111
IMA 185
inch
inch
∅ 20
∅ 24
∅ 15
∅ 20
∅ 15
-
∅ 12
∅ 12
IMA 111
IMA 185
2
2
lb/ft
lb/ft
8.35
9.4
40.020.940 - rev. 04 - 2011
IMA-US