ENGLISH
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
DESCRIPTION:
1. OPTICAL LENS: with manual focus adjustment
2. CONTROL PANEL:
a. DISPLAY: shows the various menus and the selected functions.
b. LEDS:
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
c. BUTTONS:
MENU
To select the programming functions
DOWN
To go backward in the selected functions or to decrease a value
UP
To go forward in the selected functions or to increase a value
ENTER
To confirm the selected functions
3. BRACKET: hanging bracket with 2 knobs on both sides to fasten the unit and a mounting hole to fix a
mounting hook.
4. SAFETY EYE: used to attach a safety cable when the unit is rigged (see paragraph "overhead rigging")
5. MAINS OUTPUT:.
6. MAINS INPUT: with IEC socket and integrated fuse holder; connect the supplied mains cable here.
7. COOLING FAN:
8. WIRED REMOTE CONTROL INPUT: Used to connect a simple CA-8 hand controller while the unit is
used in standalone or master/slave mode.
9. DMX OUTPUT: 3pin female XLR-connector used to connect the effect with the next unit in the DMX
chain.
10. DMX INPUT: 3pin male XLR-connector used to connect the effect with the DMX controller or with the
previous unit in the DMX chain.
JB SYSTEMS
®
OPERATION MANUAL
3/41
LED SEAWAVE 50W
ENGLISH
HOW TO SETUP:
MAIN MENU:
To select any of the functions, press the MENU button up to when the required one is shown on the
display or use the DOWN and UP buttons to browse the menu.
Select the function with the ENTER button (the display blinks).
Use DOWN and UP buttons to change the mode.
Once the required mode is selected, press the ENTER button to confirm.
To go back to the main menu without any change press the MENU button shortly. (The main menu is shown
in the chart.)
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
DMX Address
Used to set the starting address in a DMX setup.
Press the MENU button until "Addr" is shown on the
display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to change the DMX512
address.
Once the correct address shows on the display, press
the ENTER button to save it.
(To go back to the main menu without any change press
the MENU button shortly.)
Press the MENU button for about 2 seconds if you want to
exit the Menu and go back to the normal running mode.
Working Mode
Used to set the unit in master or slave mode.
Press the MENU button until "SLMd" is shown on the
display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select "MASt" (master
mode) or "SL I" (slave mode).
Once the correct mode is shown on the display, press
the ENTER button to confirm your choice.
Press the MENU button for about 2 seconds if you want to
exit the Menu and go back to the normal running mode.
Display on/off
Display on: display is always lit.
Display off: display is dark when not used.
Press the MENU button until the display shows "Led".
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select "on" (display always lit) or "oFF" (display dark when not used).
Once the mode is selected, press the ENTER button to save it.
To go back to the main menu without any change press the MENU button shortly.
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button until "dISP" is shown on the display. (normal display)
Press the ENTER button to toggle between
Press the MENU button for about 2 seconds if you want to exit the Menu and go back to the normal running
mode.
JB SYSTEMS
®
OPERATION MANUAL
(normal display) and
(display inversion).