DECLARATION BY THE MANUFACTURER
Manufacturer: DITEC S.p.A.
via Mons. Banfi, 3
21042 Caronno Pertusella (VA) - ITALY.
Herewith declares that the microwave non-contact push
button PID24 is in conformity with the provisions of the fol-
lowing EC directives:
- R&TTE Directive 1999/5/EC
- EMC Directive 2004/108/EC
Caronno Pertusella, 20-09-2011
GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally com-
petent personnel only.
Read the instructions carefully before beginning to install
the product. Incorrect installation may be a source of dan-
ger.
Packaging materials (plastic, polystyrene, etc.) must not be
allowed to litter the environment and must be kept out of
the reach of children for whom they may be a source of
danger.
Before beginning the installation check that the product is
in perfect condition.
For repairs or replacements of product only original spare
parts must be used. These instruction must be kept and
forwarded to all possible future user of the system.
To handle electronic parts, wear earthed antistatic
conductive bracelets.
1. TECHNICAL DATA
Power supply
Stand-by absorption
Operating absorption
Frequency
Output contact
Protection degree
Temperature
2. REFERENCE
[1] Cover
[2] Sensor support frame
[3] Detection module
[4] Command terminal board
[5] Detection area range adjustment trimmer
[6] Container
[7] LED / Operating indicator
[8] Detection mode selection switch
3. INSTALLATION AND ELECTRICAL CONNECTIONS
(Fig. 1) Fix the container [6] securely to a flat surface or place
a round recessed box (not supplied) in a position suitable
for the designated use and placed as shown in fig. 1 and 3.
Make the connections to the command terminal board [4],
as shown in Fig. 4.
WARNING: The product must be connected to an extra-low
voltage power source (SELV = Safety Extra Low Voltage)
which is protected from overcurrent and shortcircuiting.
Marco Zini
(Managing Director)
24 V AC/DC
50 mA
80 mA
24,150 GHz
30 V / 1 A max (resistive load)
IP43
da -20° C a +55°C
Fasten the sensor support frame [2] to the container using
the supplied screws.
NB: Avoid placing items that may move in the detection area
i.e. curtains, signs or plants.
4. ADJUSTMENTS
Selecting type of detection.
Select the type of detection using the selection switch [8].
T / TOGGLE: Toggle function.
A first detection closes the contact which remains closed
until a second detection takes place.
P / PULSE: Pulse function.
A detection activates the contact for a short period of time
(approx. 1 s).
Detection area adjustment
Adjust the detection area range by using the adjustment
trimmer [5], as shown in the figure.
-
100
5. INDICATIONS
The LED [7] comes on when the output relay is activated.
6. TROUBLESHOOTING
Problem
Cause
It does not
Power supply vol-
work
tage
Faulty connection
It does not
Sudden change in
always work
the detection area
conditions
It works by
There is an object in
itself
the detection area
The sensor is subject
to vibrations
The sensor detects
the
moving
wing
All right reserved
All data and specifications have been drawn up and checked
with the greatest care. The manufacturer cannot however
take any responsibility for eventual errors, ommisions or in-
complete data due to technical or illustrative purposes.
3
-
+
+
500
Solution
Check the power supply
Check the wiring and
the connector
Check the installation
conditions
Check the detection
area range.
Remove the object
Install the sensor firmly
Adjust the detection
door
area correctly
IP2114 • 2011-09-20
EN