Aprimatic VARIA RF Instrucciones Para La Instalación página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

10. TIMES PROGRAMMING (FIG. 1)
This programming can be done only after having turned the appliance off and on or at the end of a closing
cycle (end of the operating time).
In standard confi guration operating time and pause time are 45 seconds. These parameters satisfy most applications;
if they have to be changed, proceed as follows:
1. Press SW2 (times programming key) until hearing three long beeps: the programming phase is in progress.
2. Press the button or key of the remote control corresponding to the "Local Open" command: the countdown
starts automatically and one beep is emitted after every second elapsed.
3. Once reached the duration required for the operating time, press again the button or key of the remote
control; the countdown stops and the new setting is stored in the memory of the appliance which beeps
twice shortly to confi rm.
4. Repeat steps 2 and 3 for programming the pause time.
5. When both parameters have been programmed, the procedure stops automatically (three long beeps will be
emitted) and the appliance returns to normal mode.
Information
The pause time must always be programmed even if the selected logic is not the Automatic one: in
this case, the new setting will not affect the functioning.
If, after entering the programming phase, no key is pressed within 15 seconds, the procedure stops
automatically (time-out); any previous programming will remain valid.
If you make a mistake, quit the procedure by pressing SW2 (times programming key - see fi g.2.2):
even in this case the previous programming will remain valid.
If you want to change the parameters after the installation of the module and the latter is not easily
accessible, you can proceed as mentioned above via radio.
a - Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or TR4) until the module beeps
shortly, then release the keys.
b - Within 5 seconds, repeat the operation until the module beeps twice shortly, then release
the keys.
c - Again, within 5 seconds, repeat the operation and hold the keys pressed until hearing three short
beeps followed by three long beeps signalling that the programming phase is in progress.
Now proceed as mentioned.
11. CENTRALIZED CONTROL - VIA CABLE
If you wish to realize a system to simultaneously control, for instance, the open and close motions of more automatic
systems, connect the wires as shown below (using the optional control cable).
Information
Centralized commands have priority on local commands; for this reason, for the whole duration
of the (opening or closing) cycle controlled by a centralized command, local commands are
disabled.
Regardless of the operation logic selected, the reception of a centralized command causes the
immediate execution of the corresponding motion for the duration of the pre-set operating time.
"Stop" and "Safety" inputs remain always activated, thus enabling the user to stop or reverse the
motion in the event of dangers for people or property.