Dear customer, thanks for choosing Syncra HF, the ideal pump to create
EN
waterfalls and small waterways in your decorative pond, it also can be applied
to pressure or cavity external filters with or without UVC lamps. Our product
features a modern design and it's easy to maintain, with threaded intake and outtake, that can
connect with several standard joints and accessories, to meet all your needs.
IMPORTANT SAFETY INSTRUCTIONS
Syncra HF is in conformity with the national and international security laws. Please read
carefully and save the following instructions to use in the best way your Syncra HF.
1) Check that the tension on the pump's label is correspondent to the network tension. The
pump has to be supplied by a differential switch (protector) through which the nominal
current is lower or equal to 30mA.
2) The pump can operate IN-LINE or submerged in the water and it can be used internally and
externally.
3) Before connecting the pump to the electric network, check that the cable and the pump are
not damaged.
4) The pump has a type Z cable link. The cable and the plug cannot be substituted or repaired;
in case of damage of them substitute the entire pump.
5) CAUTION: disconnect all the submersed electrical products before doing any maintenance
in the water; in case the plug or the electric outlet are wet, disconnect the general switch
before disconnecting the electric supply cable.
6) The pump must not work without water to avoid damages to the motor.
7) The pump can be used in liquids or in environment with a temperature not higher than 35 °C/95 °F.
8) Do not use this product for different purposes other than the ones it is designed for, do not
use in swimming pools, bath tubs or similar applications where people might be immersed.
For any kind of different use, contact the retailer.
9) Avoid to use the pump with corrosive and abrasive liquids.
10) The pump has not been projected for people with handicap and children if they are not
supervised by a person responsible for their safety.
11) To avoid that accidental drips wet the plug or the socket, make a loop with the cord under the
socket level (Fig. 1).
12) Avoid to take the pump by the cord during the installation or maintenance.
USE AND MAINTENANCE
Syncra HF includes the following components (Fig. 2):
1 Completely submergible motor body insulated with bi-component resin
2 Noiseless and wear-proof rotor with hub impeller
3 O-ring + threaded volute 1" Gas (Mod. 10.0), 1½" Gas (Mod. 12.0 - 16.0)
4 4 volute tightening screws
5 Rear pump cover
6 Pre-filter
7 O-ring + stepped joint D25 mm and D30 mm with female thread 1" GAS mod. 10.0
8 O-ring + joint D38 mm with female thread 1½" GAS mod. 12.0 - 16.0
9 Mounting base
INSTALLATION
To install the Syncra HF proceed as follows:
-
Connect the joint to the pump outtake to which you can connect the hose with the appropriate
diameter.
-
Place the pump in an area of the pond, easily accessible for the maintenance operations.
-
The pump can work horizontally and vertically.
-
Unwind the supply cable where it can be safe from any kind of damage.
-
Connect the plug to a power supply socket with the same voltage as the voltage indicated
on the technical data label.