Operating Elements And Connections; Front Panel; Rear Panel; Safety Notes - Monacor PA-1200EX Consejos De Seguridad

Ocultar thumbs Ver también para PA-1200EX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GB
Please unfold page 3. Then you can always see the
operating elements and connections de scribed.

1 Operating Elements and Connections

1.1 Front panel

1 Cover panel for the insertion compartment 1
2 Cover panel for the insertion compartment 2
3 Operating LED
4 POWER switch

1.2 Rear panel

5 Mains connecting jack for the operation with
230 V~/50 Hz
6 Mains fuse
Only replace a blown fuse by one of the same type.
7 Cover plate 2
8 Screw terminals for a 24 V emergency power
supply
9 Master output "1 + 2", balanced
10 Output PACK 2 of the insertion 2, balanced
11 Output PACK 1 of the insertion 1, balanced
12 Cover plate 1

2 Safety Notes

The unit corresponds to all required directives of the
EU and is therefore marked with
WARNING The unit is supplied with hazardous
mains voltage (230 V~). Leave servicing
to skilled personnel only. Inexpert han-
dling or modification of the unit may
cause an electric shock hazard.
It is essential to observe the following items:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
G
Do not place any vessels filled with liquid, e. g. drink-
ing glasses, on the unit.
G
Do not set the unit into operation, or immediately dis-
connect the mains plug from the mains socket if
1. there is visible damage to the unit or to the mains
cable,
2. a defect might have occurred after a drop or simi-
lar accident,
3. malfunctions occur.
The unit must in any case be repaired by skilled per-
sonnel.
6
G
G
G
G
.
3 Applications
The unit has especially been designed to accept two of
the following insertions by MONACOR:
PA-1120DM
PA-1130CD
PA-1130RCD radio/CD player
PA-1200C
PA-1200RDS AM/FM radio
4 Setting-up
The unit is provided for being inserted into a rack
(482 mm/19"), but it can also be used as table top unit.
For the rack installation two rack spaces are necessary
(1 rack space = 44.5 mm).
Never pull the mains cable to disconnect the mains
plug from the mains socket, always seize the plug.
For cleaning only use a dry, soft cloth, never use
chemicals or water.
No guarantee claims for the unit and no liability
for any resulting personal damage or material dam-
age will be accepted if the unit is used for other pur-
poses than originally intended, if it is not correctly con-
nected, operated, or not repaired in an expert way.
Important for U. K. Customers!
The wires in this mains lead are coloured in ac cord -
ance with the follow ing code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:
1. The wire which is coloured green and yellow must
be con nected to the terminal in the plug which is
mark ed with the letter E or by the earth symbol
or coloured green or green and yellow.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
Warning - This appliance must be earthed.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a
disposal which is not harmful to the environ-
ment.
digital message memory
for 6 announcements
CD player
timer
,

Publicidad

Tabla de contenido
loading

Tabla de contenido