Mhouse RC2 Nstrucciones Y Advertencias Para La Instalación página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Table [A]
Memorizing the first transmitter in Mode I
1
Power the receiver: you will hear two long beeps
2
Within 5 seconds, press one of the keys in the desired pair (pair 1-2 or 3-4) on the transmitter
and hold it down
3
Release the key when you hear the first of the 3 beeps confirming the memorization
If the receiver has already memorized one or more transmitters, when it is switched on you will hear 3 short beeps. In this case you will not be
able to proceed as described above, but will have to switch to the memorization mode described in Table [B]
Even if one or more transmitters have already been memorized in Mode I, additional transmitters can be memorized in Mode I, as described
in Table [B]
Table [B]
Memorizing additional transmitters in Mode I
1
Press and hold down one of the keys in the desired pair (1-2 or 3-4) on the new transmitter to
be memorized (New TX) until you hear a beep (after approx. 5 seconds), then release the key
2
Slowly press one of the keys in the desired pair on a previously memorized transmitter (old TX)
3
Once again, press and release the key on the new transmitter you pressed according to step 1
The 3 final beeps signal that the new transmitter has been correctly memorized.
If the memory is full (30 transmitters), 6 beeps will signal that the memory is not capable of memorizing any additional transmitters.
Memorization Mode II (advanced memorization)
In this mode, each of the 4 available commands can be associated to a transmitter key, as shown in Table [C].
Table [C]
Commands available for memorization Mode II
Command
1
On-Off
2
Man Present
3
Timer 1
4
Timer 2
In this mode, the memorization procedure is performed separately for each single transmitter key; this means that 2 keys on the same
transmitter can be memorized for two commands to the same receiver, or to command different receivers as illustrated in the example
below:
Example of memorization Mode II
Key 1
On-Off on RC2 no. 1
Key 2
Key 3
Key 4
To memorize the transmitters in Mode II, refer to Tables [D] and [E].
Table [D]
Memorizing the first transmitter in Mode II
1
As soon as the receiver is powered you will hear 2 long beeps
2
Within 5 seconds, press the desired key on the transmitter to be memorized and hold it down until all
3 beeps have sounded, then release the key
3
Within 3 seconds, press the same key on the transmitter as many times as the number corresponding
to the desired command: 1 = On-Off; 2 = Man Present; 3 = Timer1; 4 = Timer2
4
After approx. 3 seconds you will hear a number of beeps corresponding to the selected command
5
Within 2 seconds, press and release the same key to confirm the programming
The 3 final beeps signal that the new transmitter has been correctly memorized. During step 4, if you do not hear the number of beeps corre-
sponding to the desired function, wait 10 seconds before abandoning the procedure, then try again.
Table [E]
Memorizing additional transmitters in Mode II
1
Press and hold down the desired key on the new transmitter (New TX) until you hear a beep
(after approx. 5 seconds), then release the key
2
Within 5 seconds, press and hold down for approx. 5 seconds a previously memorized key on a
transmitter (old TX) until you hear 2 short beeps, then release the key.
3
Within 3 seconds, press again the same key on the previously memorized transmitter (old TX) as
many times as the number corresponding to the desired command:
1 = On-Off; 2 = Man Present; 3 = Timer1; 4 = Timer2
4
After approx. 3 seconds you will hear a number of beeps corresponding to the selected command
5
Within 2 seconds, press and release the desired key on the new transmitter (new TX) to confirm the
programming
The 3 final beeps signal that the new transmitter has been correctly memorized.
If the memory is full (30 transmitters), 6 beeps will signal that the transmitter cannot be memorized.
4 RC2
Description
The first command switches on the unit, the next one switches it off, and so on
When the key is pressed the relay contact closes. When the key is released the relay contact opens
The contact remains closed for a length of time ranging from 1 sec to 9 hours (programmable as shown in Table [G])
The contact remains closed for a length of time ranging from 1 sec to 9 hours (programmable as shown in Table [G])
Timer1 on RC2 no. 2
Timer2 on RC2 no. 3
Example
Example
5s
New TX
Old TX
New TX
Man Present on RC2 no. 3
Example
X1...X4
X1...X4
Example
5s
New TX
5s
X1...X4
Old TX
X1...X4
New TX

Publicidad

Tabla de contenido
loading

Productos relacionados para Mhouse RC2

Tabla de contenido