Memorizing a new transmitter like a previously memorized transmitter
It is possible to memorize a new transmitter so that it operates exactly like a previously memorized one. If the old transmitter was memo-
rized in Mode I, the new one will also operate in Mode I and a single memorization stage will be required. If the key on the old transmitter
was memorized in Mode II, also the key on the new transmitter will be memorized in Mode II and will perform the same function. If you
wish to memorize more than one key you will have to perform a memorization procedure for each key.
Table [F]
Memorizing a new transmitter exactly like a previously memorized transmitter
1
Press the key on the new transmitter (new TX) to be memorized and hold it down for
at least 3 seconds, then release it.
2
Press the key on the previously memorized transmitter (old TX) and hold it down for at least 3 seconds,
then release it.
3
Press the key on the new transmitter (new TX) again and hold it down for at least 3 seconds,
then release it.
4
Press the key on the previously memorized transmitter (old TX) and hold it down for at least 3 seconds,
then release it.
The 3 final beeps signal that the new transmitter has been correctly memorized.
If the memory is full (30 transmitters), 6 beeps will signal that the memory is not capable of memorizing any additional transmitters.
Programming the Timers
The RC2 receiver features two independent timers (Timer1 and
Timer2) for automatic relay deactivation after a set time delay.
The deactivation time can be brought forward, compared to the
timer setting, by maintaining the "timer" command active for more
than 3 seconds or by giving an "Off" command.
The factory or default settings for the two timers are 1 minute
(Timer1) and 10 minutes (Timer2) respectively.
Table [G]
Programming the Timers
1
Press and hold down the transmitter key associated with control of the timer you wish to program.
The relay will be activated (On).
2
Hold the key down, after approx. 3 seconds the relay will be deactivated (Off)
3
Hold down the same key for approx. 10 seconds, until the relay is activated again (On).
The time measuring stage starts at this point. Release the key.
4
When the time you wish to set has elapsed, press the key associated with control of the timer.
The relay will be deactivated (Off) and the measured time will be memorized.
3 long beeps will signal that the time has been programmed successfully; the following 1 or 2 short beeps indicate whether timer1 or timer2 has
been programmed.
Clearing the Receiver Memory
There may be cases when the RC2 receiver memory has to be
cleared.
The memory can be cleared using:
- non-memorised transmitters or those which have been memori-
sed for "Timer" commands starting from point A.
- A previously memorized transmitter, starting from step N. 1
Table [H]
Clearing the memory
A
With the receiver not powered, remove the jumper from the board
(after clearing the memory, the jumper must be reinstalled).
B
Power the receiver and wait for the initial beeps
1
• With the transmitter in mode I or not memorized:
Press and hold down key 2 or key 4 on a transmitter previously memorized in mode I until you
hear a beep (after approx. 5 seconds), then release it.
• With the transmitter in mode II (On/Off or timer only):
For On/Off with open relay (Off), press the key to activate it (On), release the key, press it again and
hold it down until you hear a beep (after approx. 5 seconds), then release the key.
For timer with open relay (Off), press the key to activate the relay (On), hold down the key until the
relay is deactivated (Off) and you hear a beep (after approx. 5 seconds), then release the key
2
After 1 second, press the same key again and release it precisely during the third beep.
3
After 1 second, press the same key again and release it precisely during the third beep.
4
After 1 second, press the same key again and release it precisely during the third beep.
5
If you wish to completely erase all the data stored in the memory, press the key again within 2 seconds
and then release it.
After a few seconds, 5 beeps will signal that the memory has been cleared.
The time settings can be programmed separately for each of the
two timers, from a minimum of 1 second to a maximum of 9 hours.
Once the timer has been programmed, every command associat-
ed with it will activate the relay for the set time interval.
In order to program the timers you need to have a transmitter
memorized for timer control, then follow the steps in the table
below.
The following items may be erased:
- Transmitters only, proceeding up to step 4
- All the data (transmitters and timers), completing the procedure
up to step 5.
Example
3s
New TX
3s
Old TX
3s
New TX
3s
Old TX
Example
"Relay ON"
3s "Relay OFF"
10s "Relay ON"
"Relay OFF"
Example
5s
?...
5s
RC2 5

Publicidad

Tabla de contenido
loading

Productos relacionados para Mhouse RC2

Tabla de contenido