Adaptors; Operation; Start And Stop; Connecting The Post Driver - Atlas Copco LPD-T Instrucciones De Seguridad Y De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Safety and operating instructions
of the power source is 160 bar (limited by safety
valve adjustment).
WARNING Operating pressure
If the maximum operating pressure for the hydraulic
machine is exceeded, it can result in material
damage and personal injury.
Always run the hydraulic machine with the correct
operating pressure. See "Technical data".

Adaptors

Choose a suitable adaptor for the post. To
1)
choose the correct adaptor, see the spare parts
list or accessories catalogue.
Remove the nuts from the bottom plate.
2)
3)
Fix the adaptor to the post driver by the
fasteners.
Optional adaptors

Operation

WARNING Involuntary start
Involuntary start of the machine may cause injury.
Keep your hands away from the start and stop
device until you are ready to start the machine.
Learn how the machine is switched off in the event
of an emergency.
Stop the machine immediately in all cases of
power supply interruption.
14
Square adaptor, 54 mm (2.13
in.)
Universal adaptor:
● Square post: maximum
62x62 mm (2.44 x2.44 in.).
● Rectangular post: maximum
90x35 mm (3.54 x 1.38 in.)
● Round post: maximum Ø62
mm (Ø2.44 in.).
Round adaptor, Ø96 mm
(Ø3.78 in.)
© 2010 Atlas Copco Construction Tools AB | No. 3392 5036 90 | 2010-04-15

Start and stop

Connecting the post driver

Ensure that the hydraulic supply meets the
requirements of the post driver, see "Technical data".
Connect the hydraulic hoses. Make sure the hoses
are clean before connecting them. The connectors
are of the 'quick release' type.
The power source must be fitted with a return line
oil filter with a filter rating of 10-25µ.
Back pressure: The back pressure (return line
pressure) of the post driver should be as low as
possible and may not exceed maximum. Back
pressure, see "Technical data", measured at the
post driver in order to avoid functional
disturbances.
Oil cooler: Oil coolers must be able to stand a
pressure of minimum 10 bar (145 psi) and must
be provided with a by-pass valve opening at a
pressure of 2 bar (29 psi) in case of pulsations in
the return line.
The following is optional settings when connecting
the post driver:
Oil supply: If the oil supply of the power source
exceeds the flow prescribed, the engine's rpm
must be reduced, until correct oil flow is achieved.
Test equipment can be used, see Spare parts list.
Oil flow divider: If the oil flow cannot be adjusted
by lowering the rpm, an oil flow divider must be
installed. This will secure the post driver the
correct oil flow and lead excess oil back to the
tank (or to the operating valve block).
Pressure relief valve: To protect the post driver
against too high a pressure, the pressure relief
valve of the powerpack must be set in accordance
with the technical data. If that is not possible,
connection can be made by installing a separate
pressure relief valve. In case of doubt, contact
your nearest authorised workshop.
LPD LPD-T, LPD-RV
Original instructions

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lpd-rv

Tabla de contenido