Testing And Commissioning; Accessories On Request; Technical Characteristics - Nice Metro ME3000 Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

5) Testing and commissioning

Testing of the entire system must be conducted by experienced and
qualified personnel, who must establish what tests are necessary
depending on the risks involved. To test METRO proceed as follows:
• close the gate;
• disconnect the power supply to the control unit;
• release the gearmotor from the gate leaf as shown in paragraph
"Manual release device (Key and Lever-Operated Release)" in Chap-
ter "Instructions and Warnings for Users of the METRO Gearmotor".
• open the gate manually all the way;
• make sure the gate opens and closes smoothly without any points
of friction;
• make sure that the gate, when stopped in any position and
6) Maintenance
METRO does not require any special maintenance; however, routine
checks conducted every six months at least will ensure the long life
of the gearmotor as well as the correct and safe operation of the sys-
tem.
6.1) Disposal
METRO is made out of various types of materials, which must be
disposed of in compliance with the regulations locally in force.
The system can be dismantled and scrapped without any risks aris-
ing out of the automation itself.

7) Accessories On Request

PLA10 Vertical electric lock 12 Vac
MEA1 360° opening device

8) Technical Characteristics

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. Inany
case, the manufacturer guarantees their functionality and fitness for the intended purposes.
All the technical characteristics refer to a room temperature of 20°C (±5°C).
Models and Characteristics
Unit of measurement
Power supply
Absorbed current
Absorbed power
Incorporated capacitor
Protection class
Speed
Torque
Operating temperature
Thermal protection
Work cycle
Weight
6
PLA11 Horizontal electric lock 12 Vac
MEA2 Key-operated release mechanism
ME3000
(Vac-Hz)
230V-50Hz
(Vdc)
(A)
1.2
(W)
250
(uF)
10
(IP)
67
(Rpm)
1.14
(Nm)
300
(°C Min/Max)
-20° ÷ +50°
(°C)
140°
(%)
30
(Kg)
11
released, does not display a tendency to start moving again;
• make sure that the safety systems and mechanical stops are in
good working order;
• make sure that the screw connections are properly tightened;
• clean the inside of the box and make sure that the drain operates
properly;
• when all the checks have been completed, re-connect the gear-
motor and power the control unit;
• METRO is not equipped with any torque adjustment device, there-
fore this operation is performed by the control unit;
• measure the impact force as provided by the EN12453 and
EN12445 standards.
Maintenance consists simply in repeating the testing proce-
dure.
If sorted waste disposal is required, the materials should be sepa-
rated according to their type (electrical, aluminium, plastic parts,
etc.).
ME3010
ME3000L
230V-50Hz
230V-50Hz
1.2
1.3
250
300
10
10
67
67
1.14
0.8
300
250
-20° ÷ +50°
-20° ÷ +50°
140°
140°
40
30
11.5
11
MEA3 Lever-operated release mechanism
ME3000/110
ME3024
110V-60Hz
2.4
250
30
67
1.4
300
-20° ÷ +50°
-20° ÷ +50°
140°
30
11
24
5
120
67
1.4
250
80
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Metro me3010Metro me3000lMetro me3000/110Metro me3024

Tabla de contenido