Gallagher M350 Manual De Instrucciones página 13

Ocultar thumbs Ver también para M350:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Gallagher 3E4410 M350 M550 M650 Energizer User Manual
Install the earth system at least 10m (33 ) from any power supply earth peg,
underground telephone or power cable. Drive one 2m (6 ) earth stake into
the ground, un l only 5cm (2") remain above the ground.
Note: Poor grounding can cause
interference on telephone lines, radios
and televisions. This can be recognised
by a clicking sound on telephones.
Step 3. Connect the fence
Connect the energizer's red (FENCE)
terminal to the fence using double
insulated cable. Remove 5cm (2") of
plas c coa ng from one end of the
cable. Bend the end of the wire to
form a loop. Unscrew the red (FENCE)
terminal and insert the loop of wire.
Screw the terminal closed, ensuring
the wire is fi rmly clamped. A ach
the other end of the cable to the
fence using a joint clamp.
Step 4. Plug the
energizer
into a power outlet
Check that the light on the front
of the energizer is fl ashing.
Green
To earth
Red
To fence
Light
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M550M650

Tabla de contenido