Wolf ICBPW482418 Guía De Uso Y Mantenimiento página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

W O L F
P R O V E N T I L AT I O N H O O D
R E C E S S E D
C O N T R O LS
Controls for Pro ventilation hoods and hood
liners are recessed under the front edge of the
hood. Refer to the illustration below.
L I G H T C O N T R O L
The left rotary switch operates the halogen
lights. There are two settings,
setting can be used as a night-light. From
the
position, turn the switch to the desired
light setting, left for
and right for
setting.
H E AT L A M P C O N T R O L
If your hood is equipped with heat lamps, a
center rotary switch will control the lamps.
Each heat lamp may function independently or
both lamps may be activated simultaneously
from the single switch. From the
simply turn the switch to the right
activate the right heat lamp or to the left
activate the left lamp. When the switch is in
the vertical position
, both heat lamps will
be activated.
B L O W E R C O N T R O L
The right rotary switch that operates the
blower is variable, allowing infinite control of
the blower speed. Rotate the switch fully
counterclockwise to turn the blower off.
Blower
Control
Heat Lamps
Control
(686 mm deep
hoods only)
Halogen
Lights Control
Recessed controls
U S E & C A R E
H E AT S E N T R Y
Heat Sentry feature turns the ventilation hood
on when heat is sensed and adjusts the blower
speed automatically. The Heat Sentry feature is
activated when the exhaust temperature from
the hood reaches 95˚C and deactivated when
the exhaust temperature decreases to 85˚C.
At 95˚C the blower motor will automatically
and
. The
adjust to HIGH speed. When the sensor cools
down to 85˚C it adjusts the blower back to the
setting on the blower control. For example, if
light
blower motor is in LOW speed and threshold
temperature is reached, the blower will
increase to HIGH speed.
F I LT E R
To remove the stainless steel filters, push each
filter up at the angle it is placed in and rotate
down. Remove the center filter first. Take out
position,
the grease cups (if applicable) placed on the
to
bottom edge of the hood coinciding with the
to
bottom edge of the filters. Gloves should be
worn to provide the proper grip. Reinstall
using the reverse procedure as shown in the
illustration below. Outer filters may need to be
pushed over while the center filter is reinstalled.
IMPORTANT NOTE: DO NOT operate the
ventilation hood without the filters. This may
cause damage to the blower or other internal
components of the hood.
Grease Cup
Filter reinstallation—686 mm deep
wall hood shown
F E AT U R E
R E M O V A L
Spring
Filter
SIDE VIEW
13