Contact Id Page; Telephone Numbers To Call; Events Description; Contact Id Default - Bentel Security BGSM-G Serie Manual Del Usuario

Comunicador de alarma gsm/gprs
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Contact ID Page

This page will allow you to set up the Contact ID function.

Telephone numbers to call

Four telephone numbers of up to 20 digits (digits and + signs).
This Device will try each telephone number 3 times before considering a call unsuccessful and quitting.
, , , , , The Contact ID Codes will be sent to the first number (with Contact ID reporting protocol) that answers the call.

Events description

† Customer Code - type in a 4 character code (accepted values: digits and the letters A, B, C, D, E and F).
To send the SMS it is necessary enter a Customer Code (e.g. 1111) for the relevant event.
† Event Code - type in the Contact ID to be transmitted when the respective event occurs.
† Send - select (tick) the events to be sent.

Contact ID default

Click on this button to assign the following Event Codes to the events manage by this Device: the Sur-Gard System III / II Description
column show the label that the Sur-Gard System III and System II receivers assign to the relevant event. The Qualifier (E or R) is
automatically generated by the Device and can not be programmed.
Event Description
Input 1 activation
Input 1 Restoral
Input 2 activation
Input 2 Restoral
Input 3 activation
Input 3 Restoral
Input 4 activation
Input 4 Restoral
PSTN Line down
PSTN Line Restoral
12 V Input Loss
12 V Input Restoral
Low Battery Alert
Low Battery Restoral
Periodic Report
GSM Unit Activation
GSM Internal Buffer Full
FTC Restoral

Send Contac-ID over GPRS

If this option is enabled, this Device will only communicate Contact ID events via the GPRS network.

Periodic Reports

This Device can be programmed to send Periodic Contact ID reports. This section will allow you to select the Date and Time of the first
periodic report and the Interval between reports.
If the external power supply (connected to terminals [+12V]) and battery power supply drop at the same time, the Device
must be re-programmed after the power supply is restored, otherwise the time set for the Periodic Report could NOT be
respected.
BGSM-G
Qualifier Event Code
E
11A
R
11A
E
12A
R
12A
E
13A
R
13A
E
15A
R
15A
E
351
R
351
E
337
R
337
E
338
R
338
E
6A3
R
552
E
624
R
354
Sur-Gard System III / II Description
FIRE ZONE 001
FIRE ZONE 001
Panic Alarm ZONE 002
Panic Alarm ZONE 002
Burglary ZONE 003
Burglary ZONE 003
24 HOUR (AUXILIARY) ZONE 004
24 HOUR (AUXILIARY) ZONE 004
TELCO 1 FAULT 000
TELCO 1 FAULT 000
EXP. MOD. DC LOSS 000
EXP. MOD. DC LOSS 000
EXP. MOD. LOW BAT 000
EXP. MOD. LOW BAT 000
Periodic RF Xmission 000
Radio Xmitter Disabled 000
EVENT LOG OVERFLOW 000
FAILURE TO COMMUNICATE 000
G
G
G
G
G
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bgsm-g/amBgsm-g/eu

Tabla de contenido