Model Selection; Specifications - DART Controls CONTROL Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INPUT VOLTAGE
12 VDC ± 15%
24 VDC ± 15%
36 VDC ± 15%
* 24 volt and 36 volt units with the same current ratings are interchangeable (ie. 24 volt unit will operate with 36 volt input
and a 36 volt unit will operate with 24 volt input, same current rating).
Load current (continuous)
Speed adjustment
Speed range
Overload capacity
Current limit
Acceleration
Deceleration
Maximum speed
Minimum speed
Connections
Speed regulation
Operating temperature
Package configuration
Internal operating frequency

MODEL SELECTION

OUTPUT VOLTAGE
CONTINUOUS CURRENT
0 - 12 VDC
0 - 24 VDC
0 - 36 VDC

SPECIFICATIONS

5K Ω potentiometer or 0 to +10VDC input signal
200% for 10 seconds; 150% for one minute
adjustable 100% to 200% of full motor load, up to 200% of control current rating
adjustable - 50 to 100% of base speed
adjustable - 0 to 30% of max speed
Euro-style terminal block (14Ga. to 28Ga..)
1% of base speed via adjustable I.R. Compensation trimpot
5
10 amps D.C.
10 amps D.C.
10 amps D.C.
65E10
10 amps
30 : 1
adjustable - 0 to 10 seconds
non-adjustable - 0.5 seconds
-10°C to +45°C (14°F to 113°F)
black anodized aluminum extrusion
approximately 18K Hertz
MODEL NUMBER
65E10-12
65E10*
65E10*

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

65e10

Tabla de contenido