Wire connection

• Be sure to connect the wires matching the terminal numbers. Incorrect connection causes a trouble.
• Be sure to pass the cables through the bushing of wiring connection port of the indoor unit.
• Keep a margin (Approx. 100mm) on a wire to hang down the electric parts box at servicing, etc.
• Remove the cover of the electric parts box by taking off the mounting screws (3 positions) and pushing the
hooking section. (The cover of the electric parts box remains hanged to the hinge.)
• Connect the indoor/outdoor connection wires to the terminal block of the electric parts box.
(Do not apply tension to the connecting section of the terminal block.)
• Tighten the screws of the terminal block, and fix the wires with cord clamp attached to the electric parts box.
(Do not apply tension to the connecting section of the terminal block.)
• Using the attached thermal insulation material, seal the pipe connecting port. Otherwise, dewing may be caused.
• Mount the cover of the electric parts box without pinching wires.
(Mount the cover after cabling on the ceiling panel.)
Screws
P .C. board
Power supply
Earth screw
terminal block
1
2
1
2
3
Cord clamp
Wiring on the ceiling panel
According to the Installation Manual for the ceiling
panel, connect the connectors to the P.C. board in the
electric parts box.
Connect the sensor connector to CN201 (Blue), and
the louver motor wiring connector to CN33 (White) on
the P.C. board, respectively.
REQUIREMENT
Push
Screw
Hooking
3
section
Heat insulator B
16
Electric parts box
Cover of electric parts box
Thermal insulation to
wiring connecting port
Cord clamp
Cord clamp
CN201
CN33
Adhered surface
Heat
insulator A
Notched section
Sensor lead wire
(from ceiling panel)
Louver motor wiring
(from ceiling panel)