Identify the inside door panel. The label faces the
11
outside of the shower. The rollers are opposite
the label, and face the inside of the shower.
Outside of
the Shower
Inside of
Label Side
the Shower
Roller
Label
On the inside of the shower, hold the guide
16
against the bottom track, and slide the doors
from wall to wall. If the doors bind or do not
contact the bumpers, reposition the rollers to
raise or lower the glass panels.
Outside
Guide
of the
Shower
Outside of
the Shower
Side View
IMPORTANT! Proper application of silicone
21
sealant is critical to the long-term performance of
your shower door. Apply silicone sealant to your
shower door as instructed in the following steps.
Silicone
Sealant
Troubleshooting
Symptom: Alignment
1. Top of the door panel is tilted away from the
wall.
2. Bottom of the door panel is tilted away from
the wall.
3. Door panel does not touch the bumper.
4. Bottom track is miscut or skewed.
Symptom: Water Leaks
1. Water leaks between panels.
2. Water leaks between the wall jamb and the
door panel.
3. Water leaks under the bottom track.
Symptom: Operation (open/close)
1. Outside panel is difficult to move.
2. Inside panel is difficult to move.
1278968-2-A
Lift the inside door panel onto the inside track.
12
Install with the label facing the outside of the
shower.
If either panel needs adjustment, remove the
17
door, and position the rollers in new holes to
raise or lower the panel.
Lower the glass.
Raise the glass.
Outside the shower, lift the center guide slightly,
22
and apply silicone sealant under the center
guide.
Recommended Action
A. Remove the door panel from the top track, and lower the roller that is closest to the wall. See step 17.
A. Remove the door panel from the top track, and raise the roller that is closest to the wall. See step 17.
A. Determine whether the door panel top or bottom is closer to the wall. Then adjust the roller closest to the wall.
A. The notched wall jamb fits over the bottom track to cover any miscut or skewed cuts. Seal as directed to ensure
proper watertight seal. See step 24.
Recommended Action
A. When showering, make sure the inside panel is against the showerhead wall.
A. Adjust the door panel to line up with the wall jamb. See steps 23 and 24.
A. Check for proper silicone sealant application. See steps 23 and 24. Apply more silicone sealant in the leak location.
Recommended Action
A. Ensure a gap exists between the bottom track and the door panel. If no gap exists, lower the rollers to the next hole.
B. Ensure the rollers are properly installed. See step 13.
C. Clean any debris in the top track groove.
A. Ensure a gap exists between the bottom track and the door panel. If no gap exists, lower the rollers to the next
hole.
B. Ensure the rollers are properly installed. See step 11.
C. Clean any debris in the top track groove.
Identify the outside door panel. The label faces
13
the outside of the shower. The rollers are on the
same side as the label, and face the outside of the
shower.
Outside of
the Shower
Inside of
Label
the Shower
Side
Rollers
Label
Assemble both towel bars with a spacer on each
18
side of the panel. Use a hex wrench to tighten the
screws. Do not overtighten!
1/16"
1/4"-20 Screw
Door
Panel
Spacers
Towel Bar
Outside the shower, use silicone sealant along
23
the entire length of the wall jambs and the
bottom track.
Outside of
the Shower
2
Lift the outside door panel onto the outside track.
14
The label faces the outside of the shower.
NOTE: When the top track is tightened properly,
19
the expansion mechanism nut will be seated
against the stationary portion of the top track.
Ensure that the top track pads and the wall jambs
are pressed flush against the wall, and that the
shower door frame is installed securely. Expand
the top and bottom tracks if needed.
Pad
Pad
Top Track
Expansion Mechanism Nut
Wall Jamb
Wall Jamb
Inside the shower, use silicone sealant along the
24
entire length of the wall jambs, and where the
wall jambs meet the bottom track.
Warranty
STERLING® Warranty – Bath and Shower Doors
5-Years Limited
SP2375 5100 Series 5300 Series 5400 Series 6300 Series 6500 Series
3-Years Limited
1500 Series 1900 Series 2200 Series 4600 Series 4700 Series 4800 Series 4900 Series 5900 Series
1-Year Limited
500 Series 600 Series 660 Series 670 Series 690 Series 950 Series 2300 Series 3100 Series
Based on the classification specified above, STERLING bath and shower doors are warranted to be free of
manufacturing defects within the time of the specified model's limited warranty from date of sale.
Kohler Co. will, at its election, repair, rectify or replace a fixture when inspection by Kohler Co. discloses any such
defects occurring in normal usage within the time period of coverage stated above. Kohler Co. is not responsible
for removal or installation costs where replacement is indicated. Damages due to improper handling, installation or
maintenance are not considered manufacturing defects and are not covered by this warranty. This warranty is valid
for the original, consumer purchaser only.
To obtain warranty service, contact Sterling, either through your plumbing contractor, home center, wholesaler or
dealer, or by calling or writing Sterling, Consumer Services, 444 Highland Drive, Kohler, Wisconsin 53044, 1-800-
783-7546.
TO THE EXTENT PERMITTED BY LAW, ALL IMPLIED WARRANTIES INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
KOHLER CO. AND SELLER HEREBY DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty
lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and
exclusions may not apply to you. This warranty gives you specific legal rights. You may have other rights which
vary from state/province to state/province.
This is the exclusive written warranty for Kohler Co.
Remove the protective vinyl strips from the
15
bottom of both door panels.
Door
Panel
Vinyl Strip
On the top track, slide the caps against the
20
shower walls.
Cap
Cap