... Conversion of gas hob for use with different gas type
Nozzle table
Use only nozzles with punched marks!
Gas
type
H/E natural
gas
G 20
20 mbar
Butane
propane
G 30/31
28-30/37 mbar
Rated liquid gas consumption
Rated
thermal
load
Burner
Natural
position
gas
H
H
1,75 kW
Rear
1,60 kW
4,00 kW
Front
3,65 kW
Rear
Front
Rated
power
Butane +
propane
s
i
1,75 kW
128 g/h
3,0 kW
219 g/h
4,75 kW – 347 g/h
Minimum
output
99
0,35 kW
45
144
0,60 kW
57
65
0,38 kW
28
87
0,60 kW
39
Burner
Gas tap
Burner
Gas tap
Burner
Gas tap
Burner
Gas tap
21