WARNINGS & CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that power is off before installing, servicing or replacing fixture!
• Controlling a load in excess of the specified ratings will damage the unit and pose the risk of fire, electric shock, personal injury or death. Check your load ratings to determine the unit's suitability for your application.
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
• Use this device with COPPER OR COPPER CLAD WIRE ONLY.
• Operating Temperature: -40°F to 160°F.
• Relative Humidity: 20% to 90% non-condensing.
FEATURES
• Pole, Fixture or Electrical Box mounted Passive
Infrared Occupancy Sensor
• Adjustable Time Delay
• Adjustable Sensitivity
DESCRIPTION
Leviton's Outdoor High Bay Occupancy Sensor, Cat. No. OSFHW-CTW is specifically designed for wet indoor
and outdoor mounted areas such as parking garages, food processing plants, nurseries, greenhouses, industrial
facilities and other high ceiling applications. The OSFHW-CTW installs directly to an industrial luminaire or an
electrical junction box. It is a self-contained sensor and relay that detects motion using the passive infrared (PIR)
to sense sources (such as a person entering a room) within its field-of-view (monitored space) and automatically
switches lights ON. The controlled lights will remain ON until no motion is detected and the scheduled time-delay has
expired. The OSFHW-CTW is supplied with two interchangeable lens rings that allows the user to select between a
360 degree High Bay or Low Bay pattern and an aisle pattern with the included aisle mask.
Cat. No. OSFHW-CTW is UL listed, cUL listed and conforms to California Title 24 requirements. The Sensor's High
Bay lens is designed for 20 ft. to 40 ft. mounting heights for a symmetrical pattern which will provide coverage of 50'
to 60' diameter (refer to Figure 3). The Low Bay lens is designed for 8 ft. to 25 ft. mounting heights for a symmetrical
pattern which will provide coverage of 30' to 50' diameter (refer to Figure 4). The Sensor is sensitive to the heat
emitted by the human body. In order to initially trigger the Sensor, the source of heat must move from one zone of
detection to another.
NOTE: Occupancy sensors respond to rapid changes in temperature, so care should be taken not to mount the
device near a climate control source (i.e. radiators, air exchanges, and air conditioners). Hot or cold drafts will look
like body motion to the device and will trigger it if the unit is mounted too close. It is recommended to mount the
Occupancy Sensor at least 6 ft. away from the heating or cooling ventilation source.
INSTALLATION
NOTE: The OSFHW-CTW is supplied with two lens trim rings. The 360 degree High Bay lens (white color trim ring)
is installed at the factory with the Low Bay lens (blue color trim ring) in the carton. Choose the correct lens for your
fixture height location and add the aisle mask if desiring to block detection outside of the aisle. Refer to Figure 7 for
changing lens trim ring and adding the aisle mask. The OSFHW-CTW Sensor mounts in a 1/2" knock out hole on a
pole or the end of a luminaire or electrical box. When mounting to a pole the Sensor's field-of-view will be partially
obstructed by the pole. When mounted to a luminaire the Sensor's field-of-view may be partially obstructed by the
luminaire housing. As long as the bottom of the sensor is mounted within 1" from the bottom of the luminaire, the
field-of-view will not be affected.
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that
power is off before installing, servicing or replacing fixture!
2. The sensor comes with two lens rings, a white one for 360 degree High Bay detection (installed at factory), and
a blue one for Low Bay applications. NOTE: The aisle mask is provided to customize your detection area.
3. To change lens, unscrew the locking ring counter clockwise to remove, replace the existing lens and put the
locking ring back on; hand tighten only (refer to Figure 7). To add the Aisle Mask line up the notches of the
locking ring with the Tabs of the Aisle Mask and turn to hold in place.
4. Remove the lock-nut from the threaded nipple and insert the wires and the threaded nipple into a half inch hole
of the pole, luminaire body or electrical box.
5. Slide the lock-nut over the wires and thread clockwise on to the threaded nipple to secure the sensor firmly in
place making sure the lens is orientated towards the area to be monitored (refer to Figure 6).
6. Connect wires per Wiring Diagram as follows: BLACK lead to LINE (Hot); RED lead to LOAD; WHITE lead to
LINE (Neutral). Twist each lead tightly with circuit conductors and push firmly into the appropriate wire connector.
Screw connector on clockwise making sure that no bare wire shows below the connector.
7. Restore power at circuit breaker or fuse.
NOTE: Allow approximately two minutes for charge-up. If the lights turn ON and the LED blinks when a hand is waved
in front of the lens, then the Sensor was installed properly. If the operation is different, refer to the Troubleshooting
Section. The Sensor is factory preset to work without any adjustments. If you desire to change the factory settings,
refer to the Settings section.
SETTINGS
Time-Delay: Settings should be determined during the installation period. This adjustment controls the amount
of time the lights stay ON after the last detected motion. You may
select settings varying from 30 seconds to 30 minutes and any time
in between.
Sensitivity: Settings should be determined during the installation period.
This adjustment controls the sensitivity of the passive infrared (PIR)
detection.
NOTE: After power is turned ON, allow two minutes for this unit to warm
up before performing Time-Delay settings.
TROUBLESHOOTING
• Lights will not turn ON
- Sensor is wired incorrectly: Confirm that the sensor's wiring is done correctly and inspect visually for problems.
- Lens is dirty or obstructed: Inspect the lens visually and clean if necessary, or remove the obstruction.
• Lights will not turn OFF
- Sensor is wired incorrectly: Confirm that the sensor's wiring is done correctly and inspect visually for problems.
- Sensitivity set improperly: Adjust the SENSITIVITY dial.
• Lights turn OFF and ON too quickly
- Sensitivity set improperly: Adjust the SENSITIVITY dial.
- Time delay set improperly: Adjust the TIME DELAY dial.
WIRING DIAGRAM
Hot (Black)
Line
Sensor
120-347 VAC,
50-60 Hz
Neutral (White)
Fig. 2
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire
(Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use
during the lifetime of the product. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and
there is disclaimed liability for labor for removal of this product or re-installation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or
altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability
and fitness for a particular purpose. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
© 2015 Leviton Mfg. Co., Inc.
OUTDOOR HIGH BAY/LOW BAY PASSIVE INFRARED
OCCUPANCY SENSOR
Cat. No. OSFHW-CTW
Fluorescent: 800 VA @ 120 VAC - Ballast
1200 VA @ 277 VAC - Ballast, 1500 VA @ 347 VAC - Ballast, 1/4 Hp @ 120 VAC
INSTALLATION
• 360 degree lenses for field-of-view (included)
- Blue Lens = 8 - 25ft mounting height
- White Lens = 20 - 40ft mounting height
• Aisle covers: add included aisle mask to either lens option.
30
SEC
SENSITIVITY
Fig. 1
Black
Red
Black
Load
White
White
LIMITED LIFETIME WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
COVERAGE AREA / AIRES COUVERTES / AREA DE COBERTURA
Fig. 3
High Bay Lens (White)
Lentille pour plafonds élevés (blanche)
Lentes instalación en alto (blanca)
TOP
9.1m (30 ft)
6.1m (20 ft)
3m (10 ft)
0
3m (10 ft)
6.1m (20 ft)
9.1m (30 ft)
0
SIDE
6.1m (20 ft)
9.1m (30 ft)
12.2m (40 ft)
9.1m
6.1m
3m
(30 ft)
(20 ft)
(10 ft)
Fig. 5
High Bay Lens (White) with aisle mask
Lentille pour plafonds élevés (blanche), avec masque d'allée
Lentes instalación en alto (blanca) con bloqueadores de pasadizo
9.1m (30 ft)
6.1m (20 ft)
3m (10 ft)
0
3m (10 ft)
6.1m (20 ft)
9.1m (30 ft)
0
S
H
E
6.1m (20 ft)
L
V
E
9.1m (30 ft)
S
10
20
12.2m (40 ft)
30
MIN
9.1m
6.1m
3m
(30 ft)
(20 ft)
(10 ft)
TIME
Fig. 7
Changing Lens (adding aisle mask)
Remplacement de la lentille (et ajout du masque d'allée)
Cambio de Lentes (añada bloqueadores de pasadizo)
Tabs
Ergots
Pestañas
Locking Ring
Anneau de blocage
Anillo de bloqueo
Fig. 4
Lentille pour plafonds réguliers (bleue)
Lentes instalación en bajo (azul)
9.1m (30 ft)
6.1m (20 ft)
3.0m (10 ft)
0
3.0m (10 ft)
6.1m (20 ft)
9.1m (30 ft)
0
2.4m (8 ft)
6.1m (20 ft)
7.6m (25 ft)
0
3m
6.1m
9.1m
9.1m
(10 ft)
(20 ft)
(30 ft)
(30 ft)
Fig. 6
Sensor / Détecteur
Sensor
S
H
E
L
V
E
S
0
3m
6.1m
9.1m
(10 ft)
(20 ft)
(30 ft)
Fig. 8
Aisle Mask
Masque d'allée
Bloqueadores
de pasadizo
Notches
Wiring
Access
Encoches
Accès
Incisiones
au câblage
Acceso
de Cableado
Lens Ring
Lentille
Anillo de lentes
Sensor
Détecteur
Sensor
DI-000-OSFHW-25A
ENGLISH
Low Bay Lens (Blue)
6.1m
3.0m
0
3.0m
6.1m
9.1m
(20 ft)
(10 ft)
(10 ft)
(20 ft)
(30 ft)
Mounting
Fixation
Montaje
Inside of Pole,
Luminaire or
Electrical Box
Intérieur du poteau,
du luminaire ou
de la boîte électrique
Dentro del poste,
luminaria o
caja eléctrica
Wires / Fils
Conductores
Lock Nut / Contre-écrou
Tuerca de seguridad
Gasket / Joint
Empaquetadura
Pole Light
Installation sur poteau
Luz de poste
Sensor
Détecteur
Sensor
DI-000-OSFHW-25A

Publicidad

loading

Resumen de contenidos para Leviton OSFHW-CTW

  • Página 1 LIMITED LIFETIME WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use during the lifetime of the product.
  • Página 2 SOLO PARA MEXICO NOMBRE: DIRECCION: POLIZA DE GARANTIA: LEVITON S. de R.L. de C. V., LAGO TANA NO. 43 COL. HUICHAPAN, DEL. M. HIDALGO MÉXICO D. F., MÉXICO. CP 11290 Tel (55) 5082-1040. Garantiza este COL: C.P. producto por el término de un año en todas sus partes y mano de obra contra cualquier defecto de fabricación y funcionamiento a partir de la fecha de entrega o instalación del producto bajo las...