VENTING THE DRYER

IMPORTANT!

CHECK THE EXHAUST SYSTEM FOR PROBLEMS
The most common cause of dryer problems is poor exhaust venting. Before installing the new dryer, check the items
listed below to make sure to get the best possible performance. This can save time and money by reducing cycle
times and increasing energy effi ciency.
• DIRTY OR DAMAGED EXHAUST DUCTS. Lint builds up in exhaust ducts over time. This decreases the airfl ow and
makes the dryer work harder. Visually inspect the ducts from both ends and have them cleaned if they have not
been cleaned recently.
• WRONG VENT MATERIAL. Check the vent to make sure it is rigid or semi-rigid metal ducting. If the venting is
plastic or fl exible foil, have it replaced before using the dryer.
• RESTRICTED OR DAMAGED VENT HOOD. Check the vent hood outside. It must be clean and free of lint buildup.
Check the damper and make sure it opens fully and easily.
• EXCESSIVELY LONG VENT. Measure the length of the exhaust system and count the elbows. Use the chart below to
see if the duct is too long. If it is too long, have the duct routed to another location that is within the
venting guidelines.
• DO NOT USE PLASTIC OR FOIL VENTING. The transition duct from the dryer to the wall must be rigid or
semi-rigid metal ducting. If the old transition duct is plastic or foil, REPLACE IT with semi-rigid metal ducting.
Using the DUCT LENGTH CHART (below)
Find the existing vent hood type in the chart below.
1
Select the row that matches the number of elbows in the dryer duct run.
2
Look to the right of the elbow number for the maximum duct length for the installation. Longer duct length will result
3
in reduced drying performance, longer dry times and increased energy consumption. Extremely long ducts can even
shorten the life of the dryer.
DO NOT exceed the maximum length for the vent hood type and number of elbows used.
DUCT LENGTH CHART
Vent Hood Type
Recommended
4"
(10.2 cm )
(10.2 cm )
Only for Short-Run Installations
2 ½"
(6.35 cm )
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. Using more than four 90° elbows is not recommended.
Number of 90°
Elbows
0
1
2
3
4"
4
0
1
2
3
4
INSTALLATION INSTRUCTIONS
Maximum length of 4" (10.2 cm )
diameter rigid metal duct
65 feet (19.8 m)
55 feet (16.8 m)
47 feet (13.7 m)
36 feet ( 11.0 m )
28 feet (8.5 m)
55 feet (16.8 m)
47 feet (13.7 m)
41 feet (12.5 m)
30 feet (9.1 m)
22 feet (6.7 m)
13