Accessories - VWR 5000I Manual De Instrucciones

Agitador orbital de incubación
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
a
a
ccessorIes
ccessorIes
PLATFORMS
Platform can be used for mounting Erlenmeyer flask/media bottle clamps and test tube racks. Slides over-top included tray.
Tighten with adjustment screws. Stainless steel construction.
d
d
escrIPtIon
IMensIons
Platform
Platform
TEST TUBE RACKS - Requires Platform accessory.
d
c
escrIPtIon
Half Size Test Tube Racks
10 to 13mm Test Tube Rack
14 to 16mm Test Tube Rack
18 to 20mm Test Tube Rack
22 to 25mm Test Tube Rack
15mL Centrifuge Tube Rack
50mL Centrifuge Tube Rack
1,5 to 2mL Micro-Tube Rack
Full Size Stationary Test Tube Racks
10 to 14mm Test Tube Rack
16 to 20mm Test Tube Rack
21 to 25mm Test Tube Rack
Full Size Pivoting Test Tube Racks
13mm Test Tube Rack
16mm Test Tube Rack
20mm Test Tube Rack
25mm Test Tube Rack
30mm Test Tube Rack
13
(l
W)
x
33 x 28cm
47,5 x 47,5cm
33
28
47,5
47,5
x
cM
x
t
P
P
Ube
latforM
latforM
c
c
aPacIty
aPacIty
aPacIty
63
2
4
48
2
4
35
2
4
24
2
4
35
2
4
12
2
4
70
2
4
48
N/A
3
33
N/A
3
21
N/A
3
90
N/A
2
60
N/A
2
40
N/A
2
24
N/A
2
21
N/A
2
c
. n
.
at
o
444-7087
444-0697
Installation of Half Size Test Tube Racks:
1. Unit should be in standby mode.
2. Remove non-skid rubber mat. Slide Platform over-top included tray.
c
. n
.
at
o
3. Using the hardware provided, attach brackets to the Platform. Position brackets as
shown. The proper spacing between the brackets is 19,7cm.
444-0278
4. Align the test tube rack side-to-side with the brackets on the Platform.
444-0279
5. Press the test tube rack in place, you will hear the test tube rack clip into position. No
444-0280
mounting screws are required.
444-0281
Installation of Full Size Pivoting Test Tube Racks (Model 5000I/5000IR Only):
444-0283
444-0284
1. Unit should be in standby mode.
444-0276
2. Line up the 4 openings on the bottom of the outer rack with the four compatible
openings on the Universal Platform. Secure with the four screws provided.
3. If a tilt angle is desired, loosen wing knobs, tilt inner holder and tighten knobs.
444-7037
4. To maximize the platforms capacity for holding racks in the stationary position, remove
444-7038
the outer holder and secure the inner holder to the Universal Platform using the four
444-7039
openings on the bottom of the inner holder.
Installation of Full Size Stationary Test Tube Racks (Model 5000I/5000IR Only):
444-2955
1. Line up the two openings on the sides of the test tube rack with the two compatible
444-2956
openings on the Universal Platform.
444-2957
2. Place the washer on top of the opening on the test tube rack, place the clamp knob
444-2958
through the washer and rack and hand tighten the clamp knob to the platform.