16
7.1. Mounting of the sensor (immersion sensor)
While mounting the sensor pay attention to correct fit of the sensor and to good heat conductance.
7.2. Electrical connection
Plug in the controller via two-core power cord and standardised european plug in power socket (230 V AC).
Danger to life due to electric shock!
Kind of current (alternating current) and voltage have to be conform to the details at the type
plate.
DANGER
7.3. Disassembly and disposal
Danger to life due to electric shock!
Switch off the power supply before starting the disassembly!
Make sure that the controller cannot be switched on!
Disassemble the controller in reversed order as the mounting!
DANGER
Disposal according to the "act governing the sale, return and environmentally sound disposal of
electrical and electronic equipment (electrical and electronic equipment act, or ElektroG)".
8.
Procedure of commissioning
After electrical connection the mixer is closed automatically (homing). This is indicated with the two LED´s
flashing alternately. After the end position is achieved, the normal controlling operation is started.
9.
Functions and adjustments
The setpoint value temperature can be adjusted with a little screw driver (see chapter 9.1 Adjustment of the
setpoint value temperature). The two LED´s indicate the actual operation status or an occurred fault (see
chapter 9.2 LED displays and chapter 11. Errors and troubleshooting). With a screw driver the controller can be
switched from normal (automatic) operation to manual emergency operation (see chapter 9.7 Manual emer-
gency operation).
Operating and commissioning manual - EN
Rote LED
Red LED
Setpoint value temperature
Temperatur-Sollwert
Green LED
Grüne LED
Manual / automatic
Hand / Automatik
Adjustment knob
Stellknopf