Descargar Imprimir esta página

AirKing 4C630N/9012N Manual De Instrucciones De Operación Y Partes

Publicidad

Enlaces rápidos

MODELO 4C630N/9012N y 4C631P/9016P
29
1
2
4
5
23
22
18
30
6
21
10
8
25
9
27
20
11
22
4 24
12
19
18
28
26
7
4
17
13
16
LISTA DE REPUESTOS
Ref.
15
No. 4C630M/9012M
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Rev. P 3/05
3
32
31
33
34
35
7
35
Parte No. for Modelo
4C631N/9016N
Descripción
2010119
2010119
Botón de Oscilación
02030062GL
02030066GL
Motor
2010665
2010665
Cubierta del Motor (Frontal)
02090040
02090040
Tornillo de la Cubierta Tipo B
#7 x 7/16" PTH
02090140
02090140
Tornillo de Enlace
2010276
2010276
Enlace
02010548A
02010548A
Boton Tipo H.C.
02010163
02010163
Cubierta de la Pieza del Cuello 1
02010162B
02010162B
Placa de Trinquete
2010165
2010165
Bola de Oscilación Doble con
Resorte
2010252
2010252
Pieza del Cuello
02090051
02090051
Tornillo Phillips de Cabeza
Reforzada #7 x .390 PTH
2010131
2010131
Botón del Interruptor (Rotatorio) 1
02050009AWFPC
02050009AWFPC
Cordón Eléctrico
02090744
02090744
Tire Cuerda
2090539
2090539
Casquillo del Cordón Accionador 1
02090272
02090272
Pata de Caucho
02090045A
02090045A
Tornillo Phillips Tipo 25 #8 x 3/4" 6
2010552
2010552
Tapa del Interruptor
2060202
2060202
Placa Tracera para Colgar
2060316
2060316
Placa de Montaje
2090003
2090003
Tornillo Phillips #8 x 1-1/4"
2090529
2090529
Tuerca para Alambre
02055047
02055047
Interruptor con Cordón
Accionador
2010512P
2010512P
Cuerpo
02090521A
02090521A
Eje de Elevación
02090518
02090518
Resorte de Elevación
02090033
02090033
Tuerca Hexagonal
2010661
2010661
Cubierta del Motor (Trasera)
07091657
07091657
Vástago del Motor
02090060
02090060
Tornillo #7 x .8 PPH ZP Tipo B
2011212
2011200M
Rejilla Plástica Trasera
2010359
2010359
Tuerca de la Rejilla
2010008
2011013
Paletas
2010058
2010059
Tapa
02096217
02096214I
Rejilla Frontal
02010381A
02010381A
Ornamento de la Rejilla
8
OPERATING INSTRUCTIONS & PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO
COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
36
DESCRIPTION
AirKing 12" (30.4 cm) and 16" (40.6 cm) Wall Mounted Oscillating
Fans offer pull cord speed control, variable oscillation, a permanent
split capacitor motor and OSHA-complying front steel mesh grill with
a 6 ft (1.8m) 18/3 cord set.
37
SPECIFICATIONS
Motor ................................. 120V, 60 Hz (12", 30.4 cm)
Blade diameter .................. 12" ( 30.4 cm) Model 4C630N/9012N
Cant.
Speeds .............................. 3
1
Control .............................. Pull Cord
1
Air flow distribution ........... 90°
1
Approvals .......................... UL Listed. Close mesh Fan Guard
3
2
MODEL
4C630N/9012N
1
SPEED
HIGH
MED
2
CFM
930
780
3
M
/s
0.44
0.37
1
RPM
1450
1300
Amps
0.40
0.30
1
Watts
39
35
1
dBA
45
41
1
GENERAL SAFETY INFORMATION
1
When using electrical appliances, basic precau-
1
tions should always be followed to reduce the
risk of fire, electric shock and injury to person,
2
including the following:
1. Read all instructions before using Fan.
1
2. Make certain that the power source conforms to the electrical
1
requirements of the Fan.
1
3. Use this Fan only as described in this manual. Any other use not
2
recommended by the manufacturer may cause fire, electrical
2
shock, or injury to persons.
4. Unplug power cord before installing, servicing, or moving the Fan.
1
WARNING:
DO NOT DEPEND UPON THE ON-OFF
1
SWITCH AS THE SOLE MEANS OF DISCONNECTING
1
POWER WHEN INSTALLING OR SERVICING THE FAN.
1
1
ALWAYS UNPLUG THE POWER CORD.
1
5. This Fan must NOT be used in potentially dangerous
1
locations such as flammable, explosive, chemical-laden
2
or wet atmospheres.
1
6. DO NOT use Fan in or near a window. Rain may create an
1
electrical hazard.
1
7. The power cord is equipped with a three-prong grounded plug
1
that must be inserted into a matching receptacle. Under no
1
1
Rev. P 3/05
2084060A
WALL MOUNTED
OSCILLATING FANS
12" (30.4 cm) MODEL 4C630N/9012N
16" (40.6 cm) MODEL 4C631P/9016P
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle in-
stalled in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances. This work must
be done only by a qualified electrician, using copper wire only.
WARNING:
ADAPTER IS NOT RECOMMENDED. IMPROPER CON-
120V, 60 Hz (16", 40.6 cm)
NECTION MAY CREATE THE RISK OF ELECTROCUTION.
USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
16" (40.6 cm) Model 4C631P/9016P
WARNING:
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
PERSONAL INJURY, DO NOT REMOVE, REPLACE,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED
meets OSHA requirements.
PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED
4C631P/9016P
IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE
LOW
HIGH
MED
LOW
CENTER OR CALL 800-233-0268, MONDAY - FRIDAY,
620
1710
1500
1330
BETWEEN 8:30 AM AND 4:00 PM EST. IF THE PLUG
0.29
0.80
0.71
0.63
WARNING LABEL IS MISSING OR DAMAGED, CALL THE
1090
1545
1394
1244
TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
0.27
0.71
0.54
0.48
8. Where possible, avoid the use of extension cords. If they must be
32
77
65
57
used, minimize the risk of overheating by ensuring that they are
36
53
49
44
UL listed. Never use a single extension cord to operate more
than one Fan.
9. Do not operate any Fan with a damaged cord or plug or after the
Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.
10.Do not insert or allow fingers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when
operating, to avoid the chance of the Fan overturning. Locate the
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
13. Do not use Fan outdoors.
WARNING:
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.
1
USE OF A THREE-PRONG TO TWO-PRONG
THIS PLUG IS A SAFETY FEATURE. TO
REDUCE THE RISK OF FIRE OR ELECTRIC
SAVE THESE
INSTRUCTIONS
2084060A

Publicidad

loading

Resumen de contenidos para AirKing 4C630N/9012N

  • Página 1 4 24 Where a two-prong wall receptacle is encountered, it must be AirKing 12" (30.4 cm) and 16" (40.6 cm) Wall Mounted Oscillating replaced with a properly grounded three-prong receptacle in- Fans offer pull cord speed control, variable oscillation, a permanent...
  • Página 2 El motor está garantizado por tres años y todas las demás partes por un año, a partir de Ia fecha de compra. Toda pieza qua AirKing determine que está defectuosa en material o mano de obra y sea Groove enviada a un centro de serviclo autorizado, designado por AirKing, con los costos de envío prepagados, será, como remedio...
  • Página 3 DESCRIPCIÓN espigas, deberá reemplazarse por uno de tres espigas Los Ventiladores Oscilantes AirKing de 12" (30.4 cm) y 16" (40.6 cm) debidamente puesto a tierra e instalado de conformidad con el para Montaje en Pared cuentan con un control de velocidad accionado Código Nacional de Electricidad y todos los códigos y ordenanzas...
  • Página 4 Any part which is determined by AirKing to be detective in material or workmanship and returned to an authorized service location, Ranura as AirKing designates, shipping costs prepaid, will be, as the exclusive remedy, repaired or replaced at AirKing’s option.

Este manual también es adecuado para:

4c631p/9016p