LOCATING YOUR BUILT-IN SIDE BURNER
When determining a suitable location for your Built-In Side Burner installation, give
attention to concerns such as exposure to wind, proximity to traffic paths, and keeping
any gas supply lines as short as possible. Never locate the Summit
in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area.
Locate the Side Burner and structure so there is enough room to safely evacuate the
area in case of a fire.
CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES
WARNING: Clearance from the outside walls of the sides
and back of the Built-In Side Burner must be a minimum of
24 inches (61 cm) any surface. Refer to "Typical Gas Supply
Installation" before starting installation.
WARNING: The structure, "island" counter tops and adjacent
work areas for the Built-In Side Burner installation must be built
from noncombustible materials only.
NOTE: If you have questions on what materials are considered noncombustible, contact
you local building supplier or fire department.
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
All dimensions are to finished surfaces.
GAS INSTRUCTIONS
®
Built-In Side Burner
A
A
B
C
1
Note: For a countertop treatment: Recommended 3/4" (19 mm)
2
overhang. Notch front edge for frame to fully slide in.
WARNING: All counter top finished surfaces must be
constructed of a noncombustible material.
A
B
C
B
B
C
1
2
SIDE BURNER LOCATION
Any Surface
24" (61 cm) From Any Surface
Side Burner
24" ( 61 cm) Minimum Lid Clearance
SIDE BURNER
Cut out Dimensions
10 1/2" (26.7 cm)
3 3/4" (9.5 cm)
16 1/4" (41.3 cm)
B
A
Tolerances
+ 1/4" - 1/4" (6.35mm)
+ 1/4" - 1/4" (6.35mm)
+ 1/4" - 1/4" (6.35mm)
®