Connection Plugs; Vac, 20 Amp, Duplex Receptacle; Remove Contents From Carton - Generac GP Serie El Manual Del Propietario

Ocultar thumbs Ver también para GP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

0000.0
Figure 2-6. Hour Meter

Connection Plugs

120 VAC, 20 Amp, Duplex Recepta-
cle
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
ure
2-7. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
NOTE: Limit length of extension cords to fif-
teen feet, or less, to prevent voltage drop and
overheating of wires.
Figure 2-7. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
120 VAC, 20 Amp, GFCI Duplex
Receptacle (if equipped)
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See
ure
2-8. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater). It also pro-
vides protection with a Ground Fault Circuit
Interrupter with a press to TEST and RESET
button.
NOTE: Limit length of extension cords to fif-
teen feet, or less, to prevent voltage drop and
overheating of wires.
Owner's Manual for Portable Generator
000205
Figure 2-8. 120 VAC, 20 Amp, GFCI Duplex
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
Fig-
AC at 30 Amps (or greater). See
Use this receptacle to operate 120 Volt AC, 60
Hz, single phase loads requiring up to 3600
watts (3.6 kW) of power at 30 Amps or 240
Volt AC, 60 Hz, single phase loads requiring
up to 7200 watts (7.2 kW) of power at 30
Amps. The outlet is protected by two 25 Amp
(5.5kW), or two 30 Amp (6.5kW) push-to-
reset, or one 30 Amp 2-pole circuit breaker or,
two 30 Amp push button to reset (6.5/7.5/8.0
kW) circuit breaker.
000424
Figure 2-9. 120/240 VAC, 30 Amp Receptacle

Remove Contents from Carton

1. Open carton completely by cutting each
corner from top to bottom.
Fig-
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
Receptacle NEMA 5-20R
NEMA L14-30R
000203
Figure
2-9.
000204
7

Publicidad