OPERATIONS
Note:
New battery packs reach their full capacity after
approx. 5 charging and discharging cycles.
Recharge battery packs again if they have not
been used for a long time.
The performance of the battery pack reduces
when temperature falls below –10 °C.
Storage for a long time at temperatures above
40 °C can reduce the capacity of a battery pack.
●
Insert the plug into the socket.
-
The device conducts a self-test. Both the
LEDs glow for 1 second. The device then
goes into the stand-by mode: both LEDs
get switched off.
●
Slide the batter pack on the battery holder of
the charger.
-
The battery pack will be charged
automatically; the green LED blinks.
-
If the battery pack is too hot or too cold,
the red LED glows. The charging process
starts when the battery pack has reached
the correct charging temperature (5 °C ...
45 °C).
-
When the battery pack is fully charged,
the green LED glows. The charger
automatically switches to retention
charging.
●
Remove the battery pack and insert it in the
device.
Note:
The charged battery pack can remain on the
charger till it is to be used. There is no risk of
over-charging.
TROUBLESHOOTING
●
Red LED glows:
-
The battery pack is too hot or too cold.
-
The charging process starts when the
battery pack has reached the correct
charging temperature.
●
Red LED blinks:
-
Battery pack has not been placed correctly
on the battery holder.
-
Battery pack is defective.
TECHNICAL SPECIFICATIONS
Voltage range of
rechargeable battery
Charging current
Battery type
Nominal capacity
Approx. charging time
Mains voltage
Frequency
Weight
Dimensions (l x b x h)
6159935370 - 03
01/2009
15...21 V
1.8 A
Li-lon
1.3 / 2.6 Ah
40 min
EU
220...240 V
US
110...120 V
UK
220...240 V
50/60 Hz
0,6 kg
205x155x105mm
5 / 60