PAC models. Technical data
Absorbed power
At 15° C ambiance*
Heating Power
At 15° C ambiance*
Water flow
Air flow
Noise level
(TUV ISO/EN 354)
Power supply
Dimensions
Weight
* water temperature 26° C (79° F)
At the end of product lifetime, this one must imperatively be entrusted to a qualified
professional (refrigeration technician) in order to dismantle it in accordance with the
laws in force (recovery of gas cooling, of metallic materials which can be recycled...).
PAC16
1,7 kW
8,1 kW
5 m³/h
2600 m³/h
57,5 dB à 1m
37,5 dB à 10m
230 V / 1~ / 50 Hz
1140 x 450 x 690 mm
73,0 kg
- 48 -
PAC22
2,5 kW
12,2 kW
5 m³/h
2600 m³/h
59,6 dB à 1m
36,6 dB à 10m
78,5 kg
PAC31
3,8 kW
18,6 kW
7 m³/h
2 x 2600 m³/h
67,2 dB à 1m
47,2 dB à 10m
400 V / 3~ / 50 Hz
1140 x 450 x 1170
mm
117,0 kg