Installation with a manually operated shut-off valve without status feedback:
• Unlock the keyboard.
• Open the shut-off valve.
• Press the
The pump will begin to work after 40 seconds have
passed. The shut-off valve can still be opened during this
time!
The pump will remain switched on for some time after the tank has been pumped empty,
see finishing time.
• Close the shut-off valve after the pump has been switched off.
Because the shut-off valve does not have status feedback, it is very important to properly
check that the shut-off valve is open before starting to pump the tank empty!
3

Installation

See page 55 for the main dimensions.
Connect the panel as shown in the wiring diagrams, see pages 52 - 54.
- The following must be connected to the 8-pin connector:
- the power supply:
- the sensor:
-
It is recommended not to fit the sensor in the tank until after the set up procedure has been
completed.
- the pump:
- the relay:
An electrically operated shut-off valve can be connected to the 5-pin connector. See diagram 7-4.
vetus® Waste water control panel WWCP
key to start the pump cycle.
n
ote
12 or 24 Volt. Fit a 10A fuse in the positive (+) wire.
a sensor with float arm (WWSENSORA), see diagram 7-1;
an analogue ultrasonic sensor (SENSORA), see diagram 7-2.
The digital ultrasonic sensor (SENSORD) is not suitable!
a pump with power consumption less than 10 A can be connected di-
rectly to the panel. See diagrams 7-1 and 7-2;
a relay must be used if the pump uses more than 10 A. See diagram 7-3.
this can switch off a toilet and/or switch on a warning light when the tank
is full.
W
arning
ENGLISH
15
090427.02