Wipe-clean switch
By pressing the switch once, the wipe-
clean program will automatically be
activated:
- three-second window spray
- three wipes (minimum) with simultaneous
spraying
- three after wipes
By keeping the switch pressed, wiping with si-
multaneous spraying will remain activated.
All the wipers will work, even if these have not
been activated on the panel!
Status information
The LED above the speed or rain sensor switch
displays the status of the wiper operating sys-
tem:
On: wiper operation is active,
Off: wiper operation is not active,
Two 'series of blinks': displays selected program.
This is displayed when another program has
been set, and after the wiper operation system
has been activated.
Status LED
SWITCHES
vetus
The status LED on the con-
troller unit (between the
+ and – battery terminals)
shows the status of the wiper
controller:
- Green: the wiper controller is active,
- Flashing green: the current is too low,
- Red: internal fault,
- Off: the wiper controller is not active.
vetus® Windscreen wiper controller
-
STATUS
159
3

Installation

Controller unit
Mount the controller unit as close as possible
to the wiper motors. This means the wiring to
the motors can be short. Mount the controller
unit on a DIN rail TS35 (see p. 24)
The control panel
Place the panel somewhere the user can easily
operate it. Use a hole saw (ø 76 mm, 3" diam.) to
drill a hole in the instrument panel.
Connections
See the connection diagram on p.22.
Current
The controller unit is suitable for both 12 and
24 volts DC.
The current for which the wiper motors are
suitable must correspond to the onboard cur-
rent (12 or 24 V)
The plus cable of the controller unit must in-
clude a main fuse and a switch.
Use a smaller fuse if applicable, appropriate
DIN Rail
for the total maximum current of the 3 wiper
TS35
motors.
58
Use connecting wires with a sufficiently large
diameter. See the connection diagram for the
recommended minimum wire diameter. Con-
nect the current to the cable spades provided
(ø 5 mm).
ENGLISH
N
!
ote
101005.01
7