9
instructions for installation:
gas connection
To perform these operations the qualified installer will follow the
indications given in the "Adaptation to the various types of gas"
section.
For safety operation make sure that the supply pressure respects the
values given in the "Table of burner and injector characteristics". If
the appliance is supplied with liquid cylinder gas, make sure that
the cylinder pressure regulator conforms to the local regulations in
force.
The appliance must be connected to the gas system by a rigid metal
pipe (copper or steel) or continuous wall stainless steel flexible hose
in such a way that the appliance is not stressed in any way.
The appliance gas inlet tube
has an end nut to which is
connected the elbow union
(supplied; 1/2 thread male gas).
It can beturned depending on
installation needs.
The rigid or flexible metal supply
pipe (l max = 2mt) is connected
to the part opposite the elbow
union. Remember to put the
gaskets supplied at the two
ends of the elbow union. When
these parts are disassembled and
reassembled, always replace the
gaskets with new ones.
Once the appliance is installed, check that the gas pipe is not pinched
or damaged by mobile parts.
Important: when installation is complete, check that all the
gaskets are leaktight using a soap-based solution, never a
flame.