Operation And Maintenance; Tips And Recommendations For Use - Simu T3.5Hz02 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
9
Cancelling programming and settings
9.1- Switch off the power supply to the motor for 2 seconds.
9.2- Switch the power to the motor back on for 7 seconds.
9.3- Switch off the power supply to the motor for 2 seconds.
9.4- Switch the power to the motor back on.
- If the motor is on the end limit position (up or down), the
motor will run briefly on one direction and then in the
other, otherwise, the motor runs for 5 seconds in random
direction. The motor is now in the "cancelling" mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must
"eject" out of this mode all the motors that are not to be deleted by sending a command from their
individual control transmitter (UP or Down).
9.5- Then, validate the cancelling of the affected motor from the individual control:
- Press the PROG key of the transmitter more than 7
seconds. Maintain the pressure until the motor will first
run for 0,5 second in one direction and then the other,
and a few second later, it will run again in both direction.
The Hz02 motor is now as it was originally configured, and no transmitter and no settings is saved in its memory and is
ready for a new programming.
10

Operation and maintenance

- This drive is maintenance-free.
- Press the ▲ button on the control point to lower the motorised product.
- Press the ▼ button on the control point to raise the motorised product.
- If the motorised product is moving, briefly press the "STOP" button, the motorised product stop automatically.
- The motorised product is then stopped, briefly press the "STOP" button, the motorised product moves to the
programmed intermediate position. (To modify or delete an intermediate position, see the section §7).

Tips and recommendations for use:

Problems
The motorised product does not operate.
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and
used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in
particular of the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
www.simu.com. Emmanuel CARMIER, general director, GRAY, 12/2016.
EN
5/5
Possible causes
The overheating protection on the drive has been activated.
>
Solutions
Wait for the drive to cool down.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T5hz02T6hz02

Tabla de contenido