Simu T3.5Hz02 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
EN
S.A.S. au capital de 5 000 000 ! - Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
These instructions apply to all T3.5Hz02/T5Hz02/T6Hz02 drive, the different versions of which are available in the current
catalogue.
Field of application: T3.5Hz02/T5Hz02/T6Hz02 drive are designed to all types of roller shutters, outdoor awnings without
cassette. The installer, who must be a motorisation and home automation professional, must ensure that the drive product
is installed in accordance with the standards in force in the country in which it is installed such as EN 13659 relating to roller
shutters, EN 13561 relating to outdoor screens and awnings.
Liability: Before installing and using the drive, please read operating and installation guide carefully. Please read these
instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the
instructions detailed in the attached Safety instructions document must also be observed. The drive must be installed
by a motorisation and home automation professional, according to instructions from SIMU and the regulations applicable
in the country in which it is commissioned. It is prohibited to use the drive outside the field of application described above.
Such use, and any failure to comply with the instructions given in this guide and in the attached Safety instructions
document, absolves SIMU of any liability and invalidates the warranty. The installer must inform its customers of the
operating and maintenance conditions for the drive and must provide them with the instructions for use and maintenance,
and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation on the drive
must be performed by a motorisation and home automation professional.
If in doubt when installing the drive, or to obtain additional information, contact a SIMU adviser or go to the website
www.simu.com.
1
Installation
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- T5Hz02: The cable for the T5Hz02 can be removed. If it is damaged, replace by the same. The cable may only be
connected to the motor by qualified personnel. The connector is to be assembled without damaging the contacts. The
continuity of the earth connection must be ensured.
- T3.5Hz02 - T6Hz02: The cable for the T3.5Hz02 - T6Hz02 cannot be removed. If it is damaged, return the drive to the
After-Sales department.
Recommendations:
- Keep a minimum distance of 20 cm between two Hz.02 motors.
- Keep a minimum distance of 30 cm between Hz.02 motors and Hz transmitters. A radio appliance using the same
frequency (433,42MHz) may deteriorate our product's performance (ex. : hi-fi radio headphones).
- Drilling of the tube:
EN
1/5
T3.5Hz02/T5Hz02/T6Hz02
(230V~50Hz)
5010945K
EN- ORIGINAL INSTRUCTIONS