OPERATING INSTRUCTIONS
Cylinder/Gas line connection
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three
parts water.
2. Make sure regulator/control knob is in the "OFF" position as shown (see Figure 11).
3. Apply the leak detection check solution on the "X" location as shown (see Figure 10).
a. If any bubbles appear, remove the LP gas cylinder and reconnect, make sure the connection
is secure.
b. If you continue to see bubbles after several attempts, remove the LP gas cylinder per
"Disconnect LP Gas Cylinder" section and contact us for assistance.
c. If no bubbles appear after one minute, turn regulator/control knob to the " OFF"
position, wipe away solution and proceed.
Lighting
WARNING:
NEVER light the burner with a cover on the outdoor fire pit.
CAUTION:
Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors
and liquids.
CAUTION:
Do NOT obstruct the flow of combustion and ventilation air.
CAUTION:
Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1. Make sure all packagings have been removed from the outdoor fire pit.
2. Check for obstructions of airflow to the burner Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3. Control knob must be in the "OFF" position (Figure 12).
4. Clear small area of glass beads away from the igniter cover.
5. Connect propane cylinder per "Connecting Propane Cylinder" section.
6. Push and turn control panel counterclockwise to "High" position.
7. Use a match or a lighter to light the fire bowl.
8. Adjust flame to desired height with the control knob.
9. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height
matches illustration (Figures 13-15).
Figure 11
10