Connection Data - Lenze L−force 9400 Instrucciones Para El Montaje

Ocultar thumbs Ver también para L−force 9400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Connection data

Terminal X107
SSP94X6107
Terminal data
Flexible
With wire end
ferrule
Stripping length or contact length: 8 mm
Terminal X121
Terminal data
Flexible
With wire end
ferrule
EDKE94AZHB DE/EN/FR/ES/IT 1.0
Labelling
Description
Connection of the motor holding brake
BD1
+ (Lenze: WH)
BD2
− (Lenze: BN)
E94AZHx0101: 24 V DC, max. 5.0 A
Observe correct polarity!
Supply voltage for the motor holding brake (18 ... 30 V DC)
+ / −
Observe correct polarity!
Conductor cross−section
2
[mm
]
0.5 ... 2.5
Labelling
DI
GI
DO
SSP940X121
Conductor cross−section
2
[mm
]
0.2 ... 2.5
l
Electrical installation
[AWG]
20 ... 12
Description
Connection for external control
in accordance with IEC 61131−2
Reference potential
Connection for external feedback
in accordance with IEC 61131−2
[AWG]
24 ... 12
Connection data
Tightening torque
[Nm]
[lb−in]
Spring terminal
Tightening torque
[Nm]
[lb−in]
Spring terminal
4
41