Carel PJ32 Serie Manual De Instalación página 9

Plug-in termostato electronico digital con control de desescarche
Ocultar thumbs Ver también para PJ32 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.3 Setting the main operating parameters
The plug-in series instruments are supplied ready to use. They are in fact programmed in the factory (default settings) to
respond to the more common requirements. The programming is performed by assigning all the parameters the more frequently
required value; the table below lists the parameters and the corresponding default value.
code
/C
ambient probe calibration
/2
measurement stability (probe delay and range limit), 1 = fast
selection of probe to display (0 = ambient, 1 = defrost)
/4
/5
selection °C/°F (0=°C)
rd
control differential (hysteresis)
r1
minimum set allowed to the user
maximum set allowed to the user
r2
r3
enable alarm Ed (1=enable)
r4
set automatic variation of the Set point for night operation
c0
compressor start delay at instrument on
minimum time between 2 successive starts of the compressor
c1
c2
minimum compressor off time
c3
minimum compressor on time
Duty Cycle safety relay ON time
c4
cc
continuous cycle duration
c6
alarm bypass time after continuous cycle
type of defrost (0=heat el., 1=gas, 2=heat. el. time, 3=gas time)
d0
dI
interval between two defrosts
dt
end defrost temperature
dP
maximum defrost duration or effective duration for d0=2 or
d0=3
d4
defrosting at instrument on (1=yes)
d5
defrost delay
d6
display off during defrost (1=yes)
post-defrost dripping time
dd
d8
alarm bypass time after defrosting
d9
defrost priority over minimum compressor times (1=yes)
time basis (0 =hours/min, 1=min/s)
dC
A0
alarm/fan differential
AL
shift low temperature alarm threshold
AH shift high temperature alarm threshold
temperature alarm delay
Ad
A4
digital input configuration
A7
alarm input detection delay
fan operating mode
F0
F1
fan on temperature
F2
fans off with compressor off (1=yes)
fans off during defrost (1=yes)
F3
Fd
fan time-out during post dripping
H0
serial address
IR34S: enable defrosting, IR34C: multifunction relay function
H1
H2
disable keypad, 0=disabled
H4
disable buzzer
control set point
L1
(**) unit of measure (hereafter u. of m. in the tables).
To achieve the maximum performance from the controls, or in the case of special needs, the values of the operating parameters
can be modified. The following notes describe the factory settings and the parameters which are more frequently modified (set
point, differential, etc.). Furthermore, for convenience, all parameters which should be checked before operating the unit are
indicated.
Cod. +030221881 rel. 1.3 - 03/05/2006
description
d
d
type
default
min
max
F
-127
127
0
C
1
15
4
0
1
C
0
C
0
1
0
F
0
19
2
C
-50
127
-50
-50
127
C
60
C
0
1
0
C
-20
20
3
C
0
15
0
0
15
C
0
C
0
15
0
C
0
15
0
0
100
C
0
C
0
15
4
C
0
15
2
0
3
C
0
F
0
199
8
F
-50
127
4
1
199
F
30
C
0
1
0
C
0
199
0
C
0
1
1
0
15
F
2
F
0
15
1
C
0
1
0
0
1
C
0
C
0
19
0
F
0
127
0
F
0
127
0
0
199
C
0
C
0
4
0
C
0
199
0
0
1
C
1
F
-50
127
5
C
0
1
1
0
1
C
1
F
0
15
1
C
0
199
1
0
1
C
1
C
0
1
1
C
0
1
0
-50
127
S
4
plug-in
unit of
measure
(**)
°C/°F x 0,1
°C/°F
°C/°F
°C/°F
°C/°F
min
min
min
min
min
hours
hours
hours/min
°C/°F
min/s
min
min
hours
°C/°F
°C/°F
°C/°F
min
min
°C/°F
min
°C/°F
Tab. 3.3.1
Pagina 9 di 30

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pj32sPj32c

Tabla de contenido