GYS FLASH 10.36/48 PL Traducción De Las Instrucciones Originales página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Translation of the original instructions
Lithium Iron Phosphate Charging Mode (54 V/8 A max) :
Mode for charging 48V LiFePO4 batteries with 15 cells in series from 8 Ah to 160 Ah.. 8 step automatic
maintenance charge cycle.
Lithium Iron Phosphate Charging Mode (57.6 V/8 A max) :
Mode for charging 48 V LiFePO4 batteries with 16 cells in series from 8 Ah to 160 Ah. 8 step automatic
maintenance charge cycle.
Standard Lithium-ion charging mode (54 V/8 A max) :
Mode for charging standard 48 V Li-ion batteries with 13 cells in series from 8 Ah to 160 Ah. 8 step auto-
matic maintenance charge cycle.
Standard Lithium-ion charging mode (58.1 V/8 A max) :
Mode for charging standard lithium-ion batteries with 14 cells in series from 8 Ah to 160 Ah. 8 step auto-
matic maintenance charge cycle
In 48V lithium-ion charging mode (LFP or standard), press and hold button
charging voltages depending on the number of serial cells in your battery..
• Battery type selection :
Using button
, , select your battery type from the following three technology categories :
Lead-acid, AGM, GEL, etc.
• Load curve Lead :
The GYSflash 10.36/48 PL uses an advanced 7-step lead charging curve that guarantees the optimal performance of your lead-acid
battery.
1
Step
: Analysis
Analyses the state of the battery (charge level, polarity inver-
sion, wrong battery...)
2
Step
: Recovery (
Recovering damaged elements after deep and prolonged
discharge.
GYSFLASH 10.36/48 PL
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which
disconnect the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the Gysflash 10.36/48 PL to charge the battery, the UVP
protection must be disabled. To do this, select the Lithium charging mode and press the
button
automatically start charging.
LiFePO4
- 4 A /
- 3 A)
for 10 seconds. The charger will then deactivate the UVP protection and
NMC, NCA, Li-Po, LCO, MCO, ...
5
Step
: Charge (
Fast charge at maximum current to reach 80% charge level.
6
Step
: Absorption (
Constant voltage charge to reach 100% charge level.
for 3s to switch between 54V and 58V
- 10 A /
- 8 A)
- 43.8 V /
- 58.4 V)
EN
11

Publicidad

Tabla de contenido
loading

Tabla de contenido