Technical Data

Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
Hot water temperature
Temperature scale
Safety stop
Flow capacity at 3 bar
Hand shower (1)
Body showers, 5 jets (2)
Overhead shower (3)
Overhead shower + body showers (4)
Hand + body showers (5)
Overhead shower
Halogen spotlight
Handshower
Glass tray with shower
holder
Thermostat grip
Shut-off/selection valve
Bodyshower
Shower hose
Aluminium
profile
1.5 bar
max. 10 bar
2 – 5 bar
16 bar
max. 70°C
20 – 60°C
14,9 l/min
21,3 l/min
18,8 l/min
26,3 l/min
25,7 l/min
Fittings / Technical Data / Safety Instructions
Flow heater:
Applicable for flow heaters at min. 24 kW and 1.5 bar
flow pressure before the Shower panel. Only one
consumer possible, not two simul-taneously.
Pressure differences:
The pressures of the cold and hot water connections must
be balanced.
Safety instructions for connecting the DP Helis
ML 20 with lighting:
You only require a socket for the electrical installation of
the Shower panel. An external transformer is supplied to
operate the lighting.
Electrical socket installation must only be performed by a
qualified electrician. The complete power supply runs via
a 230 V/50 Hz AC connection and must be protected by
a 2-pole residual current operated circuit breaker with 30
mA fault current.
The relevant national regulations in the applicable version
must be observed during electrical installation. Installation
and in spection tasks must be performed by authorized
electricians. All work on the Shower Paneel must be
performed with the power disconnected.
The external transformer performance is 50 VA. A wiring
conduit with a diameter of at least 25 mm must be
provided to install the power supply cable. The
transformer must be installed in the dry area (protection
zone 3). The cable provided allows the transformer to be
installed max. approx. 7 m from the Shower Paneel. The
transformer must be accessible at all times. A damaged
connection cable cannot be replaced, and the transformer
must not be operated in this case.