Screws
Inlet
Filter
Head
2. Assemble Filtration System
Inspect the plumbing and supplies for damage.
-
Repair or replace as needed.
-
Place the mounting bracket over the port marked as the "OUTLET."
-
Attach the mounting bracket to the filter head using the screws
-
provided. Do not overtighten.
Apply thread sealant tape to the smaller threads of each of the
-
plastic nipples.
NOTE
You will need to apply four layers (four turns) of tape to the
:
threads to ensure a tight seal.
Thread nipples into the ports of the filter head.
-
:
NOTE
Tighten nipple, but stop before the hex makes contact with the
filter head.
B
1015061-2-
Apply thread sealant tape to
the smaller threads of both nipples
Nipples
Hex
Mounting
Bracket
Outlet
Filter Head