Continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J6 to position 1-2.
112. Entering the P1 Button address.
The P1 button is coded by default with address
100; if you want to change it, you must:
enter the programming mode following
the instructions described in "Entering the
programming mode";
enter code 112 and press P1; you hear a con-
fi rmation tone and the red LED start fl ashing;
dial the address you want to assign to P1.
Extensions must be coded with numbers from
001 to 200;
press P1; you hear a confi rmation tone and
the red LED go back ON without fl ashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J6 to position 1-2.
113. Entering the P2 Button address.
The P2 button is coded by default with address
101; if you want to change it, you must:
enter the programming mode following
the instructions described in "Entering the
programming mode";
enter code 113 and press P1; you hear a con-
fi rmation tone and the red LED start fl ashing;
dial the address you want to assign to P2.
Extensions must be coded with numbers from
001 to 200;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J6 to position 1-2.
114. Lock actuation time. To change the lock
actuation time (max. 10 seconds), you must:
enter the programming mode following
the instructions described in "Entering the
programming mode";
enter code 114 and press P1; you hear a con-
fi rmation tone and the red LED start fl ashing;
dial the number of seconds you want the door
lock to stay ON (3 digits from 001 to 010);
press P1; you hear a confi rmation tone and
the red LED go back ON without fl ashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J6 to position 1-2.
116. Operations with main or secondary door
keeper exchangers. The following settings are
necessary if in the system are installed main
and/or secondary door keeper exchangers.
To make the programming you must:
enter the programming mode following
the instructions described in "Entering the
programming mode";
enter code 116 and press P1; you hear a
fi rmation tone and the red LED start fl ashing;
enter address 201 if the door station operates
with 1 or more main door keeper exchangers
or address 210 if the door station operates
with 1 or more secondary door keeper ex-
changers;
press P1; you hear a confi rmation tone and
the red LED go back ON without fl ashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J6 to position 1-2.
000. Resetting default settings
After you have entered the programming mode
as described in the corresponding chapter, you
must:
dial 000 following the instructions contained
in "entering codes or addresses";
press P1; you hear a confi rmation tone and
the red LED start fl ashing;
dial 123 following the instructions contained
in "entering codes or addresses";
press P1; you hear a confi rmation tone and
the white LEDs of the camera start fl ashing;
exit the programming mode moving the jumper
J6 from 2-3 to position 1-2.
Warning. After you have carried out this
procedure all programming settings will be reset
to the default values.
Table 2
To make the programming easier and to
remind your self the stored addresses,
please fi ll in the following table
Codes
Addresses
111
- - -
112
- - -
113
- - -
114
- - -
116
- - -
con-
FR
Ci-contre, la liste des programmations
effectuées en usine; si nécessaire, les modifi er
en fonction des indications détaillées dans les
paragraphes suivants.
Programmations d'usine
- Adresse Poste de Rue = 231
- Adresse associée au poussoir P1 = 100
- Adresse associée au poussoir P1 = 101
- Durée d'activation de la gâche = 1 seconde
Entrer en mode de programmation
Enlever la plaque de rue.
Déplacer le pontet J6 de la position 1-2 sur
2-3; on entend une tonalité de programmation
et la led rouge (R) s'allume.
2-3
Mode de
programmation
Values from.. to..
231 ÷ 250
001 ÷ 200
001 ÷ 200
001 ÷ 010
201 / 210
1-2
Mode de
fonctionnement
Quitter le mode de programmation
Pour quitter le mode de programmation, il faut
nécessairement repositionner le pontet J6 de
la position 2-3 sur la position 1-2.
Utiliser les boutons-poussoirs
Pour saisir les adresses et les codes, utiliser
les boutons-poussoirs "P1" et "P2".
P1: La pression de ce bouton-poussoir permet
P2: La pression de ce bouton-poussoir permet
La pression du bouton-poussoir "P2" est
confi rmée par une tonalité émise par le haut-
parleur.
PB GN
S+
S- LP LP
PROGRAMMATIONS
3
2
1
J6
3
2
1
3
J6
2
1
J6
J1
V M
S2
S1 LP LP
Pn
P1
J6
de confi rmer la saisie d'un code ou de
passer à une phase de programmation
successive.
d'augmenter la valeur du chiffre à saisir.
Appuyer sur le bouton pour autant de fois
que le chiffre que l'on veut saisir (chiffre 1
= 1 pression; chiffre 9 = 9 pressions; chiffre
0 = 10 pressions sur le bouton "P2")
P1
P2
J6
Mi 2512
R
PB GN
S+
S- LP LP
J6
poussoir P1
poussoir P2
- 8 -

Publicidad

loading

Este manual también es adecuado para:

Ad2101agl