This instruction sheet provides you with the information required to
safely own and operate your Red Lion product. Retain these instruc-
tions for future reference.
The Red Lion product you have purchased is of the highest quality work-
manship and material, and has been engineered to give you long and reli-
able service. Red Lion products are carefully tested, inspected, and pack-
aged to ensure safe delivery and operation. Please examine your item(s)
carefully to ensure that no damage occurred during shipment. If damage
has occurred, please contact the place of purchase. They will assist you
in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR RED LION PRODUCT. KNOW
THE PRODUCT'S APPLICATION, LIMITATIONS, AND POTENTIAL
HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING
ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE!
DESCRIPTION
The pump you have purchased is a submersible effluent pump for use
in basins or lift stations and suitable for pumping effluent, wastewater, and
other non-explosive, non-corrosive liquids with up to 1/2" spherical solids.
SAFETY GUIDELINES
Make certain pump is disconnected from power source before attempting
to service or remove any component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel
oil, kerosene, etc. DO NOT use in explosive atmospheres or hazardous
locations as classified by NEC, ANSI/NFPAT. Pump should be used with
liquids compatible with pump component materials.
Do not handle the pump with wet hands or when standing on a wet or
damp surface or in water.
Do not pull the pump out of the water by the power cord, especially when
the pump is operating or connected to power source.
This pump is supplied with a grounding conductor and/or grounding-type
attachment plug. To reduce the risk of electrical shock, be certain that it is
connected to a properly grounded grounding-type receptacle.
The National Electric Code requires a ground fault circuit interrupter
(GFCI) be installed in the branch circuit supplying fountain equipment,
pools, etc.
In any installation where property damage and/or personal injury might
result from an inoperative or leaking pump due to power outages, dis-
charge line blockage, or any other reason, a back-up system(s) and/or
alarm should be used.
Support pump and piping when assembling and when installed. Failure
to do so may cause piping to break, pump to fail, motor bearing
failures, etc.
This pump's motor housing is filled with a dielectric oil for motor heat trans-
fer and lifetime lubrication of the bearings. This oil is non-toxic to aquatic life.
However, suffocation can occur if oil is left on the water surface. If oil escapes
the motor housing, it can be removed from the surface quickly by placing
newspapers on the water surface to soak up the oil.
The pump motor is equipped with an automatic resetting thermal pro-
tector and may restart unexpectedly. Protector tripping is an indication
of motor overloading as a result of excessively high or low voltage,
inadequate wiring, incorrect motor connections, or a defective motor
or pump.
CAUTION: THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY
A GROUND FAULT CIRCUIT INTERRUPTER
CAUTION: THIS PUMP HAS BEEN EVALUATED FOR USE WITH
WATER ONLY
1. Check the pump label for proper voltage required. Do not connect to
RL-33SC
2. If pump is supplied with a 3-prong electrical plug, the third prong is
RL-50SC
3. Check local electrical and building codes before installation. The
4. To conform to the National Electrical Code, all pumps must be wired
5. Pump should be connected or wired to its own circuit with no other
6. The flexible PVC jacketed cord assembly mounted to the pump must
1. Pump must be installed in a suitable gas tight basin which is at least
2. Pump features a 1-1/2" female NPT discharge.
3. Pump must be placed on a hard level surface. Never place pump
4. A check valve must be used in the discharge line to prevent back flow
ELECTRICAL CONNECTIONS
voltage other than that shown.
to ground the pump to prevent possible electrical shock hazard. DO
NOT REMOVE the third prong from the plug. A separate branch circuit
is recommended. Do not use an extension cord. Do not cut plug from
the cord. If the plug is cut or the cord is shortened, then this action will
void the warranty.
installation must be in accordance with their regulations as well as the
most recent National Electrical Code (NEC).
with 14 AWG or larger wire. For runs to 250', 14 AWG wire is sufficient.
For longer runs, consult a qualified electrician.
outlets or equipment in the circuit line. Fuses and circuit breaker
should be of ample capacity in the electrical circuit.
not be modified in any way.
OPERATION
11" in diameter and 24" deep, and vented in accordance with local
plumbing codes.
directly on clay, earth or gravel surfaces.
of liquid into the basin. The check valve should be a free flow valve that
will easily pass solids.
CAUTION: For best performance of check valves, when handling
solids install in a horizontal position or at an angle of no more than 45°.
Do not install check valve in a vertical position as solids may settle in
valve and prevent opening on start-up.
INSTALLATION TYPIQUE
Gas tight basin 11" dia. & 24" deep min.
Bassin antibactérien d'un diamètre minimal
compris entre 11 po et 24 po.
Recipiente hermético al gas de 11" diámetro y
de un mínimo de 24" de profundidad.
Fig. 1
8"-11" on level • 8 po á 11 po á niveau
• 8" a 11" en el nivel
1