JAZZ GB2 VIDEO DOOR ENTRY SYSTEM KIT - HOUSE
PRECAUCIONES DE SEGURIDAD
- Always disconnect the power supply
before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by authorised personnel.
The wiring must run at least 40 cm away from any other wiring.
-
-
On the power supply unit:
Do not overtighten the screws on the connector.
w
Install the power supply unit in a dry protected location free from the risk of dripping or splashing water.
w
wAvoid locations that are humid, dusty or near heat sources.
wEnsure that the air vents are free from obstruction so that air can circulate freely.
wTo avoid damage, the power supply unit must be firmly secured in place.
wTo prevent electric shock, do not remove the cover or handle the wires connected to the terminals.
CHARACTERISTICS
( )
*
-
Video door entry system with simplified wiring (non-polarised 2-wire bus).
-
Up to 4 access panels (DP-GB2A distributor required for more than one access panel) per
installation.
-
Up to 2 apartments per installation.
-
Maximum 4 Pentha monitors per installation.
-
In installations with 1 apartment, maximum 4 Pentha monitors.
-
In installations with 2 apartments, maximum 4 Pentha monitors (example 2 monitors per
apartment).
-
Confirmation tone when the call button is pressed.
-
Visual signals on the door panel for people with impaired hearing.
-
Proximity key reader for door opening (output 'CV-' and 'CV+' on the door panel).
-
DC lock release.

SYSTEM OPERATION

-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. At this moment, the apartment's monitors receive the
call. If another apartment is called by mistake, press the button for the correct apartment and the
first call will be cancelled.
-
In systems with several access doors, the other door panel(s) will be automatically disconnected. If
another visitor tries to call, a number of telephone tones will be heard to indicate that the system is
busy and LED
will illuminate.
-
The call lasts for 40 seconds. The image appears on the monitor (with code 0 'apartment 1' or code
16 if the call is in 'apartment 2') when receiving the call without the visitor knowing.
If the call is not answered within 40 seconds, LED
- To establish communication, press option
logo on the front of any slave monitor in the apartment, and LED
If the monitor is a PENTHA GB2/H with icon
between 15 and 25 cm away from the monitor to ensure maximum audio quality during
communication with the door panel.
-
Communication will last for one and a half minutes or until option
communication has finished, LEDs
and will turn off and the channel will be freed.
1
-
To open the door, press option
on the screen during the call or communication processes: one
press will activate the lock release for 5 seconds and LED
-
To activate the aux. output, press option
processes: one press will activate the aux. output for 5 seconds and LED
seconds.
-
Proximity reader: To open the door without making a call, hold the access key to the proximity
reader of the door panel, the door will be activated for 5 seconds and LED
Note: Access keys configured from factory.
5 seconds.
-
For a description of the functioning and setup of the Pentha monitor, see the monitor's user manual.
( )
For more information, see the TJAZZ PENTHA user manual (code 50122152).
*
https://doc.golmar.es/search/manual/50122152
will turn off and the channel will be freed.
on the screen of the master monitor or the
Golmar
on the door panel will illuminate.
on the front, make sure that the hearing aid is
on the screen is pressed. When
will also illuminate for 5 seconds.
2
on the screen during the call or communication
will also illuminate for 5
will also illuminate for
2
JAZZ GB2 VIDEO DOOR ENTRY SYSTEM KIT - HOUSE
INSTALLATION OF THE DOOR PANEL
( )
*
Location of the door panel:
Locate the top of the door panel at a height of 1.65m.
Wiring the door panel:
To a c c e s s t h e c o n n e c t i o n
terminals, remove the nameplate
label.
( )
*
Description of the door panel illumination LEDs (for low light conditions).
( )
*
Description of the visual signals on the door panel.
( )
*
Configuring call/door panel mode with or without shield.
( )
*
Configuring the contact type for lock release and auxiliary device output.
( )
*
Configuring card reader illumination mode/LED function mode (low light conditions).
( )
*
Managing the access keys.
Setting the door panel communication volume.
If the audio volume of the door panel is too low after turning it on, follow these steps:
-
Call the apartment.
- The call is received in the apartment. Establish communication by pressing option
screen of the master monitor or the
apartment.
-
Then press the button used to call the apartment for 3 seconds until a number of confirmation
tones are heard and door panel communication LED starts to blink.
-
Each press on the call button will increase the door panel volume and blink speed of the LED.
There are 5 volume settings and the blink speed of LED
blink - low to high volume. After reaching setting 5, maximum blink speed and volume, the next
setting is 1, minimum blink speed and volume (carousel mode).
-
To save the volume setting, keep the button pressed until a number of confirmation tones are
heard and the door panel communication LED turns on.
( )
*
For more information, see the TJAZZ PENTHA user manual (code 50122152).
https://doc.golmar.es/search/manual/50122152
1850
1650
1450
Then connect the wiring to the connector
strip of the electronic module, following
the instructions in the wiring diagrams.
Golmar
logo on the front of any slave monitor in the
will increase for each. Slow to fast
3
AP+
AP- C1 NA1
CV-
CV+
BUSBUS
on the

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

50122152

Tabla de contenido